ABB ACS800 Firmware Manual page 135

Crane control program
Hide thumbs Also See for ACS800:
Table of Contents

Advertisement

See figures below for control connection for control using digital inputs and
Potentiometer Reference.
1)
See the wiring diagram on page
if used as power ON ackn signal.
*
To be configured using respective
pointer parameters
2)
Considering the function pointer is
configured with an inverted signal
rpm
A
338
X20
1
VREF
Reference voltage -10 V DC
2
GND
1 kohm < R
X21
1
VREF
Reference voltage 10 V DC
1 kohm < R
2
GND
3
AI1+
Speed reference 0(2) ... 10 V, R
4
AI1-
5
AI2+
By default, not in use. 0(4) ... 20 mA, R
100 ohm
6
AI2-
7
AI3+
By default, not in use. 0(4) ... 20 mA, R
100 ohm
8
AI3-
9
AO1+
Motor speed 0(4) ... 20 mA
speed, R
10
AO1-
11
AO2+
Output current 0(4) ... 20 mA
nom. current, R
12
AO2-
X22
1
DI1
Forward Start
2
DI2
Reverse Start
3
DI3
Brake Acknowledge (1= brake open) *
4
DI4
Slowdown (0= Slowdown active)*
5
DI5
Fast Stop (0= Fast Stop active)
6
DI6
7
+24 V
+24 V DC, max. 100 mA
8
+24 V
9
DGND1 Digital ground
10
DGND2 Digital ground
11
DI IL
Start interlock (0 = stop)
X23
1
+24 V
Auxiliary voltage output, non-isolated, 24 V
DC, 250 mA
2
GND
X25
1
RO11
2
RO12
3
RO13
X26
1
RO21
2
RO22
3
RO23
X27
1
R031
2
R032
3
R033
< 10 kohm
L
< 10 kohm
L
in
0 ... motor nom.
=
< 700 ohm
L
0 ... motor
=
< 700 ohm
L
2) *
1)
Relay output 1
Open Brake
Relay output 2
Running
Relay output 3
Inverted fault
Application macros, control location EXT1/EXT2
> 200 kohm
=
in
=
in
135