Setting Up Communication Through A Fieldbus Adapter Module - ABB ACS800 Firmware Manual

Crane control program
Hide thumbs Also See for ACS800:
Table of Contents

Advertisement

Setting up communication through a fieldbus adapter module

Fieldbus adapters for several communication protocols are available (for example,
PROFIBUS and Modbus). Rxxx type fieldbus adapter modules are mounted in
expansion slot 1 of the drive. Nxxx type fieldbus adapter modules are connected to
channel CH0 of the RDCO module.
Note: For instructions on setting up an RMBA-01 module, see section
communication through the Standard Modbus Link
Before configuring the drive for fieldbus control, the adapter module must be
mechanically and electrically installed according to the instructions given in the
hardware manual of the drive, and the module manual.
The following table lists the parameters which need to be defined when setting up
communication through a fieldbus adapter.
Parameter
Alternative
settings
COMMUNICATION INITIALISATION
98.02
NO
FIELDBUS
ADVANT
STD MODBUS
CUSTOMISED
98.07
ABB DRIVES
GENERIC
CSA 2.8/3.0
ADAPTER MODULE CONFIGURATION
51.01 MODULE
TYPE
51.02 (FIELDBUS
These parameters are adapter-module-specific. For more information, see the module manual.
PARAMETER 2)
Note that not all of these parameters are necessarily visible.
• • •
51.26 (FIELDBUS
PARAMETER 26)
51.27 FBA PAR
(0) DONE
REFRESH*
(1) REFRESH
51.28 FILE CPI
xyz (binary coded
FW REV*
decimal
Setting for
fieldbus control
FIELDBUS
ABB DRIVES
GENERIC or
CSA 2.8/3.0
on page 233.
Function/Information
Initialises communication between drive and
fieldbus adapter module. Activates module set-up
parameters (Group 51).
Selects the communication profile used by the
drive. See section
Communication profiles
249.
249
Displays the type of the fieldbus adapter module.
Validates any changed adapter module
configuration parameter settings. After refreshing,
the value reverts automatically to DONE.
Displays the required CPI firmware revision of the
fieldbus adapter as defined in the configuration file
stored in the memory of the drive. The CPI firmware
version of the fieldbus adapter (refer to Par. 51.32)
must contain the same or a later CPI version to be
compatible. x = major revision number; y = minor
revision number; z = correction number. Example:
107 = revision 1.07.
231
Setting up
on page
Fieldbus control

Advertisement

Table of Contents
loading