Programmable Analogue Outputs; Update Cycles In The Crane Control Program; Settings; Diagnostics - ABB ACS800 Firmware Manual

Crane control program
Hide thumbs Also See for ACS800:
Table of Contents

Advertisement

Programmable analogue outputs

Two programmable current outputs (0/4 to 20 mA) are available as standard, and
two outputs can be added by using an optional analogue I/O extension module.
Analogue output signals can be inverted and filtered.
The analogue output signals can be proportional to motor speed, process speed
(scaled motor speed), output frequency, output current, motor torque, motor power,
etc.
It is possible to write a value to an analogue output through a serial communication
link.

Update cycles in the Crane control program

Output
AO / standard
AO / extension
1)
Update cycle in the motor temperature measurement function. See group

Settings

Parameter
Group
OUTPUTS
30.22
Group
MEAS
Group
AO
Group
MODULES

Diagnostics

Actual signal
01.22,
01.28,
Warning
IO CONFIG
Cycle
24 ms
24 ms (1000 ms
Additional information
15 ANALOGUE
AO value selection and processing (standard outputs)
Supervision of the use of optional AO
35 MOT TEMP
AO in motor temperature measurement
96 EXTERNAL
Optional AO value selection and processing
98 OPTION
Activation of optional I/O
Additional information
01.23
Values of the standard outputs
01.29
Values of the optional outputs
Improper use of optional I/O
1)
)
61
35 MOT TEMP
MEAS.
Program features