Index
Name/Selection
EDIT
83.02
EDIT COMMAND
NO
PUSH
DELETE
PROTECT
UNPROTECT
83.03
EDIT BLOCK
1 ... 15
83.04
TIMELEVEL SEL
12 ms
100 ms
1000 ms
Description
Stop to edit mode. Program can be edited.
Selects the command for the block placed in the location defined with
parameter 83.03. The program must be in the editing mode (see parameter
83.01).
Home value. The value automatically restores to NO after an editing command
has been executed.
Shifts the block in location defined with parameter
blocks one location up. A new block can be placed in the emptied location by
programming the Block Parameter Set as usual.
Example: A new block needs to be placed in between the current block
number four (parameters 84.20 ... 84.25) and five (parameters 84.25 ...
84.29).
In order to do this:
- Shift the program to the editing mode with parameter 83.01.
- Select location number five as the desired location for the new block with
parameter 83.03.
- Shift the block in location number 5 and the following blocks one location
forward with parameter 83.02. (selection PUSH)
- Program the emptied location number 5 with parameters 84.25 to 84.29 as
usual.
Deletes the block in location defined with parameter
following blocks one step down.
Activation of the Adaptive Program protection. Activate as follows:
- Ensure the Adaptive Program operation mode is START or STOP (parameter
83.01).
- Set the passcode (parameter 83.05).
- Change parameter
83.02
When activated:
- All parameters in group 84 excluding the block output parameters are hidden
(read protected).
- It is not possible to switch the program to the editing mode (parameter 83.01).
- Parameter
83.05
is set to 0.
Inactivation of the Adaptive Program protection. Inactivate as follows:
- Ensure the Adaptive Program operation mode is START or STOP (parameter
83.01).
- Set the passcode (parameter 83.05).
- Change parameter
83.02
Note: If the passcode is lost, it is possible to reset the protection also by
changing the application macro setting (parameter
MACRO).
Defines the block location number for the command selected with parameter
83.02.
Block location number
Selects the execution cycle time for the Adaptive Program. The setting is valid
for all blocks.
12 milliseconds
100 milliseconds
1000 milliseconds
83.03
83.03
to PROTECT.
to UNPROTECT.
99.02
FbEq
3
1
and the following
2
and shifts the
3
4
5
APPLICATION
1 = 1
1
2
3
Actual signals and parameters
211