Programmable Digital Inputs; Update Cycles In The Crane Control Program; Settings; Diagnostics - ABB ACS800 Firmware Manual

Crane control program
Hide thumbs Also See for ACS800:
Table of Contents

Advertisement

62

Programmable digital inputs

The drive has seven programmable digital inputs as a standard. Nine extra inputs
are available if optional digital I/O extension modules are used.

Update cycles in the Crane control program

Input
DI / standard
DI / extension

Settings

Parameter
Group
DIR
Group
SELECT
Group
REFERENCING
Group
INPUTS
22.01
30.03
30.05
30.22
42.02
98.03...96.05

Diagnostics

Actual signal
01.17
01.40
Warning
IO CONFIG
Fault
I/O COMM ERR
Program features
Cycle
6 ms
20 ms
Additional information
10 START/STOP/
DI as start, stop, direction
11 REFERENCE
DI in reference selection, or reference source
12 STEP
DI in step reference selection
16 SYST CTRL
DI as external Run Enable, fault reset or user macro change signal
DI as acceleration and deceleration ramp selection signal
DI as external fault source
DI in motor overtemperature supervision function
Supervision of optional I/O use
DI as mechanical Brake Acknowledge signal
Activation of the optional digital I/O extension modules
Additional information
Status of the standard digital inputs.
Example: 0000001 = DI1 is on, DI2 to DI6 and DIL are off.
Bit
Value
Input
Values of the optional digital inputs
Improper use of optional I/O
Communication loss to I/O
6
5
4
0
0
0
DIL
DI6
DI5
3
2
1
0
0
0
DI4
DI3
DI2
0
1
DI1