ABB ACS800 Firmware Manual page 215

Crane control program
Hide thumbs Also See for ACS800:
Table of Contents

Advertisement

Index
Name/Selection
92.03
MAIN DS ACT2
0 ... 9999
92.04
AUX1 DS ACT3
0 ... 9999
92.05
AUX1 DS ACT4
0 ... 9999
92.06
AUX1 DS ACT5
0 ... 9999
92.07
AUX2 DS ACT6
0 ... 9999
92.08
AUX2 DS ACT7
0 ... 9999
92.09
AUX2 DS ACT8
0 ... 9999
92.10
MSW B10 PTR
-255.255.31 ...
+255.255.31 / C.-
32768 ... C.32767
92.11
MSW B13 PTR
-255.255.31 ...
+255.255.31 / C.-
32768 ... C.32767
92.12
MSW B14 PTR
-255.255.31 ...
+255.255.31 / C.-
32768 ... C.32767
92.13
START DS TRA
2
11
Description
Selects the address from which the Actual signal 2 is read to the Main Data
Set.
Parameter index
Selects the address from which the Actual signal 3 is read to the Auxiliary Data
Set.
Parameter index
Selects the address from which the Actual signal 4 is read to the Auxiliary Data
Set.
Parameter index
Selects the address from which the Actual signal 5 is read to the Auxiliary Data
Set.
Parameter index
Selects the address from which the Actual signal 6 is read to the Auxiliary Data
Set.
Parameter index
Selects the address from which the Actual signal 7 is read to the Auxiliary Data
Set.
Parameter index
Selects the address from which the Actual signal 8 is read to the Auxiliary Data
Set.
Parameter index
Selects the address from which the
Parameter index or a constant value:
- Parameter pointer: Inversion, group, index and bit fields. The bit number is
effective only for blocks handling boolean inputs.
- Constant value: Inversion and constant fields. Inversion field must have value
C to enable the constant setting.
Selects the address from which the
Parameter index or a constant value:
- Parameter pointer: Inversion, group, index and bit fields. The bit number is
effective only for blocks handling boolean inputs.
- Constant value: Inversion and constant fields. Inversion field must have value
C to enable the constant setting.
Selects the address from which the
Parameter index or a constant value:
- Parameter pointer: Inversion, group, index and bit fields. The bit number is
effective only for blocks handling boolean inputs.
- Constant value: Inversion and constant fields. Inversion field must have value
C to enable the constant setting.
Defines the starting data set where the drive writes the Status Word, Actual
signal 1 and Actual signal 2.
Data set number 2 is the starting address. Can be used for Standard drives.
Data set number 11 is the starting address. Can be used for multidrives.
03.02
Main Status Word bit 10 is read from.
03.02
Main Status Word bit 13 is read from.
03.02
Main Status Word bit 14 is read from.
Actual signals and parameters
215
FbEq
1
2