Fcw With Pos; Faulted Int Info - ABB ACS800 Firmware Manual

Crane control program
Hide thumbs Also See for ACS800:
Table of Contents

Advertisement

03.37 FCW WITH POS

Bit
Name
0 ... 2
Reserved
3
START
4
POS BIT 0
5
POS BIT 1
6
POS BIT 2
7
RESET
8
POS BIT 3
9
POS BIT 4
10
POS BIT 5
11 ... 15
Reserved

04.01 FAULTED INT INFO

The FAULTED INT INFO Word includes information on the location of faults PPCC
LINK, OVERCURRENT, EARTH FAULT, SHORT CIRCUIT, ACS800 TEMP,
TEMP DIF and POWERF INV (see
03.17 FAULT WORD 5
Bit
Name
0
INT 1 FLT
1
INT 2 FLT
2
INT 3 FLT
3
INT 4 FLT
4
INT 5 FLT
5
INT 6 FLT
6
INT 7 FLT
7
INT 8 FLT
8
INT 9 FLT
9
INT 10 FLT
10
INT 11 FLT
11
INT 12 FLT
12 ... 14
Reserved
Description
Follower Start command from Master
Position multiplying factor bit 0. For more details see
section
Control location EXT1/EXT2 supervision mismatch
Position multiplying factor bit 1. For more details see
section
Control location EXT1/EXT2 supervision mismatch
Position multiplying factor bit 2. For more details see
section
Control location EXT1/EXT2 supervision mismatch
Follower drive Reset command from Master
Position multiplying factor bit 3. For more details see
section
Control location EXT1/EXT2 supervision mismatch
Position multiplying factor bit 4. For more details see
section
Control location EXT1/EXT2 supervision mismatch
Position multiplying factor bit 5. For more details see
section
Control location EXT1/EXT2 supervision mismatch
03.05 FAULT WORD
and chapter
Fault
tracing).
Description
INT 1 board fault
INT 2 board fault
INT 3 board fault
INT 4 board fault
INT 5 board fault
INT 6 board fault
INT 7 board fault
INT 8 board fault
INT 9 board fault
INT 10 board fault
INT 11 board fault
INT 12 board fault
1,
03.06 FAULT WORD
Fieldbus control
277
2,

Advertisement

Table of Contents
loading

Table of Contents