FAULT
CAUSE
MOTOR 1 TEMP
Measured motor temperature has exceeded
fault limit set with parameter 35.03.
(4312)
3.15 FW 4 bit 1
MOTOR 2 TEMP
Measured motor temperature has exceeded
fault limit set with parameter 35.06.
(4313)
3.15 FW 4 bit 2
NO MOT DATA
Motor data is not given or motor data does not
match with inverter data.
(FF52)
3.06 FW 2 bit 1
OVERCURR xx
Overcurrent fault in inverter unit of several
parallel connected inverter modules. xx (1...12)
(2310)
refers to inverter module number.
3.05 FW 1 bit 1 and
4.01
OVERCURRENT
Output current exceeds trip limit.
(2310)
3.05 FW 1 bit 1
OVERFREQ
Motor is turning faster than highest allowed
speed due to incorrectly set minimum/
(7123)
maximum speed, insufficient braking torque or
3.05 FW 1 bit 9
changes in load when using torque reference.
Trip level is 40 Hz over operating range
absolute maximum speed limit (the Direct
torque control mode active) or frequency limit
(Scalar control active). Operating range limits
are set with parameters
mode active) or
control active).
OVER SWFREQ
Switching frequency is too high.
(FF55)
3.06 FW 2 bit 9
20.01
and
20.02
(DTC
20.07
and
20.08
(Scalar
WHAT TO DO
Check value of fault limit.
Let motor cool down. Ensure proper motor
cooling: Check cooling fan, clean cooling
surfaces, etc.
Check value of fault limit.
Let motor cool down. Ensure proper motor
cooling: Check cooling fan, clean cooling
surfaces, etc.
Check motor data parameters
99.04
... 99.09.
Check motor load.
Check acceleration time.
Check motor and motor cable (including
phasing).
Check encoder cable (including phasing).
Check motor nominal values from group
START-UP DATA
to confirm that motor model
is correct.
Check that there are no power factor correction
or surge absorbers in motor cable.
Check motor load.
Check acceleration time.
Check motor and motor cable (including
phasing).
Check that there are no power factor correction
capacitors or surge absorbers in motor cable.
Check encoder cable (including phasing).
Check minimum/maximum speed settings.
Check adequacy of motor braking torque.
Check applicability of torque control.
Check need for brake chopper and resistor(s).
Check motor parameter settings (parameter
group
99 START-UP
DATA)
Ensure that ID run has been completed
successfully.