288

Fault messages generated by the drive

FAULT
CAUSE
ACS800 TEMP
Drive IGBT temperature is excessive. Fault trip
limit is 100%.
(4210)
3.05 FW 1 bit 3
ACS TEMP xx y
Excessive internal temperature in inverter unit
of several parallel connected inverter modules.
(4210)
xx (1...12) refers to inverter module number
3.05 FW 1 bit 3 and
and y refers to phase (U, V, W).
4.01
AI < MIN FUNC
Analogue control signal is below minimum
allowed value due to incorrect signal level or
(8110)
failure in control wiring.
3.06 FW 2 bit 10
(programmable
Fault Function
30.01)
AP [message]
Message generated by an EVENT block in the
Adaptive Program.
BACKUP ERROR
Failure when restoring PC stored backup of
drive parameters.
(FFA2)
BC OVERHEAT
Brake chopper overload
(7114)
3.17 FW 5 bit 4
BC SHORT CIR
Short circuit in brake chopper IGBT(s)
(7113)
3.17 FW 5 bit 2
BRAKE ACKN
Unexpected state of brake acknowledge signal
(FF74)
3.15 FW 4 bit 3
BRAKE SLIP FLT
The brake slipped and the motor speed
exceeded the motor slip speed
(FFF3)
period of slip fault delay
3.33 CraneFW bit 3
BR BROKEN
Brake resistor is not connected or it is
damaged.
(7110)
Resistance rating of brake resistor is too high.
3.17 FW 5 bit 0
Fault tracing
42.11
for a
42.12
time.
WHAT TO DO
Check ambient conditions.
Check air flow and fan operation.
Check heatsink fins for dust pick-up.
Check motor power against unit power.
Check ambient conditions.
Check air flow and fan operation.
Check heatsink fins for dust pick-up.
Check motor power against unit power.
Check for proper analogue control signal
levels.
Check control wiring.
Check Fault Function parameters.
Consult the documentation or author of the
Adaptive Program.
Retry.
Check connections.
Check that parameters are compatible with
drive.
Let chopper cool down.
Check parameter settings of resistor overload
protection function (see parameter group
BRAKE
CHOPPER).
Check that braking cycle meets allowed limits.
Check that drive supply AC voltage is not
excessive.
Replace brake chopper.
Ensure brake resistor is connected and not
damaged.
See parameter group
42 BRAKE
Check connection of brake acknowledgement
signal.
Check brakes.
Check resistor and resistor connection.
Check that resistance rating meets
specifications. See appropriate drive hardware
manual.
27
CONTROL.

Advertisement

Table of Contents
loading