Rdio-01 Digital I/O Extension; Control Using Joystick - ABB ACS800 Firmware Manual

Crane control program
Hide thumbs Also See for ACS800:
Table of Contents

Advertisement

136

RDIO-01 digital I/O extension

1)
Considering the function pointer is
configured with an inverted signal
*
To be configured using respective
pointer parameters

Control using Joystick

Name
Description
Start/Stop Control
Selecting the source for start and stop signals of the two
external control locations, EXT1 and EXT2
for EXT1
Selecting between EXT1 and EXT2
Defining Start/Stop selection
Defining the direction control
Selecting the DI for Slowdown
Selecting the signal for Fast Stop
Selecting the signal for High-end limit
Selecting the signal for Low-end limit
Selecting the signal for Zero Position
Referencing EXT1
Selecting the source for the speed reference (If
unipolar)
Selecting the source for the speed reference (If Bipolar)
(If AI1 is used: Setting analogue input AI1 limits, scale,
inversion)
Setting the reference limits
Setting the speed (frequency) limits
Setting the Slowdown reference
Setting acceleration and deceleration times
Setting Joystick Warning delay
Application macros, control location EXT1/EXT2
24 - 230 V AC
N
X11
1
2
X12
1
2
3
4
DI1A
High-end limit (0 = Emergency stop)
DI1B
High-end limit
DI2A
Low-end limit (0 = Emergency stop)
DI2B
Low-end limit
DI3A
DI3B
Set parameters
11.02
10.01
10.03
10.09
10.10
10.12
10.13
10.16
11.03
11.03
(13.01, 13.02, 13.03,
13.04, 13.05, 30.01)
11.04
11.05
20.02, 20.01, (20.08,
20.07)
11.12
22.02, 22.03, 22.10
11.13
1) *
1) *
Parameter value
EXT 1
DI1
REQUEST
DI4
AI1/JOYSTICK
AI1 BIPOLAR
2 seconds

Advertisement

Table of Contents
loading

Table of Contents