Pr.
Pr.
group
140
F200
141
F201
142
F202
143
F203
144
M002
145
E103
147
F022
148
H620
149
H621
150
M460
151
M461
152
M462
153
M463
154
H631
155
T730
156
H501
157
M430
158
M301
159
A005
160
E440
161
E200
162
A700
163
A704
164
A705
165
A710
166
M433
167
M464
168
5. PARAMETERS
5.1 Parameter list
Name
Backlash acceleration
stopping frequency
Backlash acceleration
stopping time
Backlash deceleration
stopping frequency
Backlash deceleration
stopping time
Speed setting switchover
PU display language
selection
Acceleration/deceleration
time switching frequency
Stall prevention level at 0 V
input
Stall prevention level at 10
V input
Output current detection
level
Output current detection
signal delay time
Zero current detection
level
Zero current detection time 0 to 10 s
Voltage reduction
selection during stall
prevention operation
RT signal function validity
condition selection
Stall prevention operation
selection
OL signal output timer
AM terminal function
selection
Automatic switchover
frequency range from
bypass to inverter
operation
User group read
selection
Simple
Simple
Simple
Frequency setting/key lock
operation selection
Automatic restart after
instantaneous power
failure selection
First cushion time for
restart
First cushion voltage for
restart
Stall prevention operation
level for restart
Output current detection
signal retention time
Output current detection
operation selection
Minimum
Setting range
setting
increments
0 to 590 Hz
0.01 Hz
0 to 360 s
0.1 s
0 to 590 Hz
0.01 Hz
0 to 360 s
0.1 s
0, 2, 4, 6, 8, 10, 12, 102,
1
104, 106, 108, 110, 112
0 to 7
1
0 to 590 Hz, 9999
0.01 Hz
0 to 400%
0.1%
0 to 400%
0.1%
0 to 400%
0.1%
0 to 10 s
0.1 s
0 to 400%
0.1%
0.01 s
0, 1, 10, 11
1
0, 10
1
0 to 31, 100, 101
1
0 to 25 s, 9999
0.1 s
1 to 3, 5 to 14, 17, 18,
21, 24,
32 to 34, 36, 46,
1
50, 52 to 54, 61,
62, 67, 70,
87 to 90, 91 to 98
0 to 10 Hz, 9999
0.01 Hz
0, 1, 9999
1
0, 1, 10, 11
1
0 to 3, 10 to 13
1
0 to 20 s
0.1 s
0 to 100%
0.1%
0 to 400%
0.1%
0 to 10 s, 9999
0.1 s
0, 1, 10, 11
1
Initial value
Refer to
Customer
page
setting
FM
CA
1 Hz
354
0.5 s
354
1 Hz
354
0.5 s
354
4
422
322
9999
349
150%
409
200%
409
150%
464
0 s
464
5%
464
0.5 s
464
1
409
0
500
0
409
0 s
235,
409
1
435
9999
532
0
337
0
324
597, 604,
0
606
0 s
597
0%
597
150%
597
0.1 s
464
0
464

Hide quick links: