 Input signals (from the inverter to the master module)
Input signals to the master module are as follows. (Output signals from the inverter)
Device No.
RX0
Forward running
RX1
Reverse running
RX2
Running (terminal RUN function)
RX3
Up to frequency (terminal SU function)
RX4
Overload alarm (terminal OL function)
Instantaneous power failure (terminal
RX5
IPF function)
Frequency detection (terminal FU
RX6
function)
RX7
Error (terminal ABC1 function)
RX8
— (terminal ABC2 function)
RX10
— (DO0 function)
RX11
— (DO1 function)
RX12
— (DO2 function)
RX20
Monitoring
RX21
Frequency setting completion (RAM)
Frequency setting completion (RAM,
RX22
EEPROM)
Torque command / torque limit setting
RX23
completion (RAM)
Torque command / torque limit setting
RX24
completion (RAM, EEPROM)
RX25
Instruction code execution completed
RX3A
Error status flag
RX3B
Remote station ready

5.21.4 Details of the remote register

The following device numbers are for the station number 1.
For the station number 2 and later, the device numbers are different. (Refer to the manual for the CC-Link master module for
the correspondence between device numbers and station numbers.)
722
5. PARAMETERS
5.21 CC-Link IE Field Network (FR-A800-GF)
Signal
0: Other than forward running (during stop or reverse rotation)
1: Forward running
0: Other than reverse running (during stop or forward rotation)
1: Reverse running
• Functions assigned to terminals RUN, SU, OL, IPF, FU, ABC1 and ABC2 are
activated.
• These signals are set in the initial setting. Using Pr.190 to Pr.196, output
signals assigned to the device numbers can be changed.
• Functions assigned to Pr.313 to Pr.315 are activated.
• No signal is assigned in the initial setting. Use Pr.313 to Pr.315 to assign
signals.
After "1" is set in the monitor command (RY20), and the monitored value is set in
the remote register RWr26 to RWr2F, "1" is set in this signal. When "0" is set in
the monitor command (RY20), "0" is set in this signal.
After "1" is set in the frequency setting command (RY21) and the set frequency is
written to the inverter RAM, "1" is set in this signal. When "0" is set in the
frequency setting command (RY21), "0" is set in this signal.
After "1" is set in the frequency setting command (RY22) and the set frequency is
written to the inverter RAM and EEPROM, "1" is set in this signal. When "0" is set
in the frequency setting command (RY22), "0" is set in this signal.
After "1" is set in the torque command / torque limit (RY23) and the torque
command / torque limit value is written to the inverter RAM, "1" is set in this signal.
When "0" is set in the torque command / torque limit (RY23), "0" is set in this
signal.
After "1" is set in the torque command / torque limit (RY24) and the torque
command / torque limit value is written to the inverter RAM and EEPROM, "1" is
set in this signal. When "0" is set in the torque command / torque limit (RY24), "0"
is set in this signal.
After "1" is set in the instruction code execution request (RY25) and the
processes corresponding to the instruction codes (RWw10, 12, 14, 16, 18 and
1A) are executed, "1" is set in this signal. When "0" is set in the instruction code
execution request (RY25), "0" is set in this signal.
When an inverter error occurs (protective function is activated), "1" is set in this
signal.
When the inverter goes into the ready status upon completion of initial setting
after power-on or hardware reset, "1" is set in this signal.
When an inverter error occurs (protective function is activated), "0" is set in this
signal.
The signal is used as an interlock during the write to/read from the master
module.