Motor Overspeeding Detection - Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

5.10.13 Motor overspeeding detection

The Overspeed occurrence (E.OS) is activated when the motor speed exceeds the overspeed detection level. This function
prevents the motor from accidentally speeding over the specified value, due to an error in parameter setting, etc.
Pr.
Name
374
Overspeed detection
H800
level
*1
The motor maximum frequency is set in Pr.702 Maximum motor frequency. When Pr.702 = "9999 (initial value)", the Pr.84 Rated motor
frequency is used as the maximum motor frequency.
Motor speed
Pr.374
ALM
NOTE
• During the encoder feedback control operation or under Vector control, the motor speed is compared against Pr.374. Under
Real sensorless vector control or PM sensorless vector control, the output frequency is compared against Pr.374.
Initial value
Setting range
0 to 590 Hz
9999
9999
Coast to stop
Time
ON
E.OS
Description
If the motor rotation speed exceeds the speed set in Pr.374 during
encoder feedback control, Real sensorless vector control, Vector
control or PM sensorless vector control, Overspeed occurrence
(E.OS) occurs, the inverter output is shut off.
If the speed exceeds "the maximum speed (Pr.1, Pr.18) + 20 Hz"
during encoder feedback control, Real sensorless vector control, or
Vector control, E.OS occurs.
During PM sensorless vector control, E.OS occurs when the speed
exceeds the "maximum motor frequency + 10 Hz"
5.10 (H) Protective function parameter
1
2
3
4
*1
.
5
6
7
8
9
10
421