Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual page 543

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

Pr.
284
Deceleration detection
A106
function selection
Overspeed detection
285
*1
A107
frequency
292
Automatic acceleration/
F500
deceleration
639
Brake opening current
A108
selection
640
Brake operation frequency
A109
selection
641
Second brake sequence
A130
operation selection
642
Second brake opening
A120
frequency
643
Second brake opening current 130%
A121
644
Second brake opening current
A122
detection time
645
Second brake operation time
A123
at start
646
Second brake operation
A124
frequency
647
Second brake operation time
A125
at stop
648
Second deceleration speed
A126
detection selection
650
Second brake opening current
A128
selection
651
Second brake operation
A129
frequency selection
*1
The speed deviation excess detection frequency is used when Vector control compatible option is mounted during Vector control. (Refer to
259
for details.)
 Connection diagram
Sink logic
Pr.184 = 15
Pr.190 = 20
Power
supply
Multi-speed signal
Brake opening completion signal
*1
The input signal terminals differ by the settings of Pr.178 to Pr.189.
*2
The output signal terminals differ by the settings of Pr.190 to Pr.196.
542
5. PARAMETERS
5.14 (A) Application parameters
Initial
Name
value
0
9999
0
0
0
0
3 Hz
0.3 s
0.3 s
6 Hz
0.3 s
0
0
0
MCCB
R/L1
S/L2
T/L3
Start signal
STF
RH
RUN(BOF)
AU(BRI) ∗
(BRI)
SD
Setting
range
0
The deceleration detection function disabled.
The protective function activates when the deceleration speed of the
1
deceleration operation is not normal.
The Brake sequence fault (E.MB1) is activated when the difference
0 to 30 Hz
between the detection frequency and output frequency is equal to or
greater than the setting value under encoder feedback control.
9999
Overspeed detection disabled.
0
Normal operation
Operation with the shortest acceleration/deceleration time.(Refer to
1, 11
page
365.)
Operation with the optimum acceleration/deceleration time.(Refer to
3
page
365.)
5, 6
Lift operation 1, 2. (Refer to
7
Brake sequence mode 1
8
Brake sequence mode 2
0
Brake opening by output current
1
Brake opening by motor torque
0
Brake closing operation by frequency command
Brake closing operation by the actual motor rotation speed (estimated
1
value)
0
Normal operation when the RT signal is ON
7
Second brake sequence 1 when the RT signal is ON
8
Second brake sequence 2 when the RT signal is ON
9999
First brake sequence is valid when the RT signal is ON
0 to 30 Hz
Refer to Pr.278.
0 to 400%
Refer to Pr.279.
0 to 2 s
Refer to Pr.280.
0 to 5 s
Refer to Pr.281.
0 to 30 Hz
Refer to Pr.282.
0 to 5 s
Refer to Pr.283.
0, 1
Refer to Pr.284.
0, 1
Refer to Pr.639.
0, 1
Refer to Pr.640.
MC
Mechanical
brake
U
V
Motor
W
24VDC
∗3
MC
∗2
Brake opening request
signal (BOF)
1
SE
Description
page
368.)
Set the second brake sequence function.
The second brake sequence function is
enabled when the RT signal is ON.
page

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a820-00167 (2.2k)Fr-a820-00046-gf (0.4k)Fr-a820-00250 (3.7k)Fr-a820-00105-gf (1.5k)Fr-a820-00077 (0.75k)Fr-a820-00250-gf (3.7k) ... Show all