 Machine end orientation connection diagram (Vector control)
• To perform machine end orientation control, the following settings are required.
-
Install a plug-in option (FR-A8AP/FR-A8AL or FR-A8APR) and a control terminal option (FR-A8TP) to the inverter, a motor end
encoder to the control terminal option, and a machine end encoder to the plug-in option.
-
Set "1" in Pr.862 Encoder option selection.
-
Set Pr.393 Orientation selection = "10 to 12". (Refer to
-
Set the gear ratio by setting Pr.394 Number of machine side gear teeth and Pr.395 Number of motor side gear teeth. (Refer to
page
568.)
MCCB
Three-phase
AC power
supply
Forward rotation start
Reverse rotation start
Orientation command
Contact input common
*1
Single-phase power supply (200 V/50 Hz, 200 to 230 V/60 Hz) is used for the fan for a 7.5 kW or lower dedicated motor.
*2
The pin number differs according to the encoder used.
*3
Use Pr.178 to Pr.182, Pr.185, or Pr.1899 (input terminal function selection) to assign the function to a terminal. (Refer to
*4
Use Pr.190 to Pr.192, or Pr.195 (output terminal function selection) to assign the function to a terminal. (Refer to
*5
Connect the encoder so that there is no looseness between the motor and motor shaft. Speed ratio must be 1:1.
*6
Earth (ground) the shield of the encoder cable to the enclosure using a tool such as a P-clip. (Refer to
*7
For the differential line driver, set the terminating resistor selection switch to the ON position. (Refer to
Note that the terminating resistor switch should be set to the OFF position (initial status) when sharing the same encoder with another unit (NC,
etc.) having a terminating resistor under the differential line driver setting.
For the complementary, set the switch to the OFF position.
*8
For terminal compatibility between the FR-A8TP and the FR-JCBL/FR-V7CBL, refer to the Instruction Manual of the FR-A8TP.
*9
A separate power supply of 5 V/12 V/15 V is necessary according to the encoder power specification. When the encoder output is the differential
line driver type, only 5 V can be input. Make the voltage of the external power supply same as the encoder output voltage, and connect the external
power supply between PG and SD. If using the 24V power supply of the FR-A8TP, 24V power can be supplied from terminal PG24.
When performing encoder feedback control and Vector control together, an encoder and power supply can be shared.
*10 When a stop position command is input from outside, a plug-in option FR-A8AX is required. Refer to
command.
*11 To enable terminal OH, set Pr.876 Thermal protector input = "1 (initial value)". (Refer to
 Encoder orientation gear ratio setting (Pr.394, Pr.395) (Vector control)
• Set the encoder orientation gear ratio for machine end orientation control.
568
5. PARAMETERS
5.14 (A) Application parameters
MC
Inverter
R/L1
U
S/L2
V
W
T/L3
FR-A8TP
PA3
STF
PAR3
STR
∗3
X22
PB3
SD
PBR3
∗4
ORA
Differential
PZ3
ORM
∗4
PZR3
Complementary
SE
PG
SD
SD
Terminating
resistor ON
PG
SD
∗7
∗8
OFF
FR-A8AX
FR-A8AP
∗10
X15
PA1
X14
PA2
Differential
X1
PB1
X0
PB2
Complementary
DY
PZ1
Terminating
PZ2
resistor ON
PG
∗7
SD
OFF
PG
SD
page
565.)
SF-JR motor with encoder
U
V
IM
W
E
Earth
(Ground)
∗2
C
R
A
N
Encoder
B
P
∗5
H
K
∗6
(-)
(+)
5 VDC power
∗9
supply
∗2
A
Machine end
Machine end
Machine end
encoder
encoder
encoder
A
(differential
(differential
(differential
B
line driver)
line driver)
line driver)
B
Encoder
Z
Z
∗5
+
-
∗6
(-)
∗9
(+)
Power supply
For 24 V complementary type (SF-V5RU)
MCCB
MC
OCR
SF-V5RU
∗1
Three-phase
FAN
AC power
supply
Inverter
U
U
V
V
IM
W
W
E
Earth
(Ground)
FR-A8TP
PC
Thermal
relay
External
OH
G1
protector
thermal relay
input ∗11
SD
G2
∗2
PA3
A
PAR3
B
PB3
C
Differential
PBR3
D
Encoder
F
PZ3
Complementary
PZR3
G
S
PG
Terminating
resistor ON
SD
R
∗7
PG24
∗8
∗6
OFF
∗9
FR-A8AP
∗2
PA1
A
Machine end
Machine end
Machine end
encoder
encoder
encoder
PB1
B
Differential
Encoder
Z
PZ1
Complementary
PG
+
Terminating
resistor ON
SD
-
∗7
PG
SD
∗6
OFF
Power supply ∗9
(-)
(+)
∗8
page
page
87.)
page
92.)
page 558
for the external stop position
page
399.)
∗5
∗5
page
496.)
450.)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a820-00167 (2.2k)Fr-a820-00046-gf (0.4k)Fr-a820-00250 (3.7k)Fr-a820-00105-gf (1.5k)Fr-a820-00077 (0.75k)Fr-a820-00250-gf (3.7k) ... Show all

Table of Contents