Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual page 179

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

Pr.
Pr.
group
495
M500
496
M501
497
M502
498
A804
*17
N011
500
*17
N012
501
502
N013
503
E710
504
E711
505
M001
516
F400
517
F401
518
F402
519
F403
522
G105
539
N002
*17
N100
541
547
N040
548
N041
549
N000
550
D012
551
D013
552
H429
553
A603
554
A604
555
E720
556
E721
557
E722
560
A712
561
H020
563
M021
178
5. PARAMETERS
5.1 Parameter list
Name
Remote output selection
Remote output data 1
Remote output data 2
PLC function flash
memory clear
Communication error
execution waiting time
Communication error
occurrence count display
Stop mode selection at
communication error
Maintenance timer 1
Maintenance timer 1
warning output set time
Speed setting reference
S-pattern time at a start of
acceleration
S-pattern time at a
completion of acceleration
S-pattern time at a start of
deceleration
S-pattern time at a
completion of deceleration
Output stop frequency
MODBUS RTU
communication check time
interval
Frequency command sign
selection
USB communication
station number
USB communication check
time interval
Protocol selection
NET mode operation
command source selection
PU mode operation
command source selection
Frequency jump range
PID deviation limit
PID signal operation
selection
Current average time
Data output mask time
Current average value
monitor signal output
reference current
Second frequency search
gain
PTC thermistor protection
level
Energization time carrying-
over times
Minimum
Setting range
setting
increments
0, 1, 10, 11
1
0 to 4095
1
0 to 4095
1
0, 9696 (0 to 9999)
1
0 to 999.8 s
0.1 s
0
1
0 to 4, 11, 12
1
0 (1 to 9998)
1
0, 9998, 9999
1
1 to 590 Hz
0.01 Hz
0.1 to 2.5 s
0.1 s
0.1 to 2.5 s
0.1 s
0.1 to 2.5 s
0.1 s
0.1 to 2.5 s
0.1 s
0 to 590 Hz, 9999
0.01 Hz
0 to 999.8 s, 9999
0.1 s
0, 1
1
0 to 31
1
0 to 999.8 s, 9999
0.1 s
0, 1
1
0, 1, 9999
1
1 to 3, 9999
1
0 to 30 Hz, 9999
0.01 Hz
0 to 100%, 9999
0.1%
0 to 3, 10 to 13
1
0.1 to 1 s
0.1 s
0 to 20 s
0.1 s
*2
0 to 500 A
0.01 A
*3
*3
0 to 3600 A
0.1 A
0 to 32767, 9999
1
0.5 to 30 kΩ, 9999
0.01 kΩ
(0 to 65535)
1
Initial value
Refer to
page
FM
CA
0
466
0
466
0
466
0
614
0 s
630
0
630
0
630
0
345
9999
345
60 Hz
50 Hz
422
0.1 s
354
0.1 s
354
0.1 s
354
0.1 s
354
9999
686
9999
652
0
665
0
666
9999
666
0
630
9999
380
9999
380
9999
408
9999
570
0
570
1 s
346
0 s
346
*2
Inverter rated
346
current
9999
606
9999
394
0
424
Customer
setting

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a820-00167 (2.2k)Fr-a820-00046-gf (0.4k)Fr-a820-00250 (3.7k)Fr-a820-00105-gf (1.5k)Fr-a820-00077 (0.75k)Fr-a820-00250-gf (3.7k) ... Show all

Table of Contents