Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual page 266

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

Speed limit
AU
Terminal 2
AU
Terminal 4
[Pr. 858 = 0]
Terminal 1
[Pr. 868 = 0]
Speed
setting
filter
RT
RL
Multi-speed
selection
RM
[Pr.4 to 6,
RH
24 to 27,
232 to 239]
REX
Option
Operation
panel
Parameter
[Pr. 808, Pr. 809]
Maximum
frequency
[Pr. 1]
Terminal 1
[Pr. 868 = 5]
Speed
setting
filter
Analog input offset
adjustment
[Pr. 849]
Terminal 2 bias [C2, C3 (Pr. 902)]
Terminal 2 gain [Pr. 125, C4 (Pr. 903)]
Terminal 4 bias [C5, C6 (Pr. 904)]
Terminal 4 gain [Pr. 126, C7(Pr. 905)]
RT
[Pr. 822 = 9999]
[Pr. 822]
[Pr. 74]
[Pr. 822 = 9999]
[Pr. 832 = 9999]
[Pr. 832]
[Pr. 74]
[Pr. 832 = 9999]
Terminal 1 bias [C12,C13(Pr. 917)]
Terminal 1 gain [C14,C15(Pr. 918)]
RT
[Pr. 822 = 9999]
[Pr. 822]
[Pr. 74]
[Pr. 822 = 9999]
RT
[Pr. 832 = 9999]
[Pr. 832]
[Pr. 74]
[Pr. 832 = 9999]
5.4 Torque control under Real sensorless vector control and Vector control
Analog
input
selection
[Pr. 73]
Operation Mode
[Pr. 79]
[Pr. 807 = 1]
Reverse
Terminal 1 input 0 to 10V
rotation
Forward
Terminal 1 input -10 to 0V
rotation
Forward
Terminal 1 input 0 to 10V
rotation
Reverse
Terminal 1 input -10 to 0V
rotation
Maximum/minimum
Acceleration/deceleration processing
setting
[Pr.1]
[Pr.2]
[Pr.7]
When [Pr. 807 =2] and [Pr. 1 Maximum
frequency] is the speed limit,
acceleration/deceleration processing is not
performed.
Speed limit selection
[Pr. 807 = 0]
[Pr. 807 = 2]
A
[Pr.8]
5. PARAMETERS
1
2
3
4
5
6
7
8
9
10
265