Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual page 648

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

Read/
Item
write
Output
frequency /
Read
H6F
speed
Output current
Read
H70
Output voltage
Read
H71
Special monitor
Read
H72
Read
H73
Special monitor
selection No.
Write
HF3
Fault record
Read
H74 to H77
Operation command
Write
HF9
(extended)
Operation command Write
HFA
Inverter status
Read
H79
monitor (extended)
Inverter status
Read
H7A
monitor
Set frequency
H6D
(RAM)
Read
Set frequency
H6E
(EEPROM)
Set frequency
HED
(RAM)
Write
Set frequency
HEE
(RAM, EEPROM)
Inverter reset
Write
HFD
Batch clearing of
Write
HF4
fault records
Instruction
code
H0000 to HFFFF: Output frequency in 0.01 Hz increments
(The display can be changed to the rotations per minute using Pr.37, Pr.144,
and Pr.811. (Refer to page
H0000 to HFFFF: Output current (hexadecimal)
Increment 0.01 A (FR-A820-03160(55K) or lower, FR-A840-01800(55K) or
lower)
Increment 0.1 A (FR-A820-03800(75K) or higher, FR-A840-02160(75K) or
higher)
H0000 to HFFFF: Output voltage (hexadecimal) in 0.1 V increments
H0000 to HFFFF: Monitor data selected in the instruction code HF3
Monitor selection data (Refer to
H0000 to HFFFF: Two latest fault records
H74
H75
H76
H77
Fault record display example (instruction code H74)
With the read data H30A0
(Last fault : THT)
(Present fault : OPT)
b15
0
(Refer to
page 742
Control input commands such as the Forward rotation command (STF) signal
and the Reverse rotation command (STR) signal can be set. (For the details,
refer to
page
650.)
The states of the output signals such as the Forward rotation output, Reverse
rotation output, and Inverter running (RUN) signals can be monitored. (For
the details, refer to
Read the set frequency/speed from the RAM or EEPROM.
H0000 to HFFFF: Set frequency in 0.01 Hz increments
(The display can be changed to the rotations per minute using Pr.37, Pr.144,
and Pr.811. (Refer to page
Write the set frequency/speed into the RAM or EEPROM.
H0000 to HE678 (0 to 590.00 Hz): frequency in 0.01 Hz increments
(The display can be changed to the rotations per minute using Pr.37, Pr.144,
and Pr.811. (Refer to page
To change the set frequency consecutively, write data to the inverter RAM.
(Instruction code: HED)
H9696: Inverter reset
As the inverter is reset at the start of communication by the computer, the
inverter cannot send reply data back to the computer.
H9966: Inverter reset
When data is sent normally, ACK is returned to the computer, and then the
inverter is reset.
H9696: Batch clearing of fault records
Data description
page
424.))
page 424
for details on selection No.)
b15
b8 b7
Second fault in past
Latest fault
Fourth fault in past
Third fault in past
Sixth fault in past
Fifth fault in past
Eighth fault in past
Seventh fault in past
b8
b7
0 1 1 0 0 0 0
1
0 1 0 0 0 0 0
Last fault
Present fault
(H30)
(HA0)
for details on fault record read data.)
page
651.)
page
424.))
page
424.))
5.15 (N) Communication operation parameters
Number of
data digits
(format)
4 digits (B.E/D)
4 digits (B.E/D)
4 digits (B.E/D)
4 digits (B.E/D)
2 digits (B.E1/
D)
2 digits (A1, C/
D)
b0
4 digits (B.E/D)
b0
4 digits (A,C/D)
2 digits (A1, C/
D)
4 digits (B.E/D)
2 digits (B.E1/
D)
4 digits (B.E/D)
4 digits (A,C/D)
4 digits (A,C/D)
4 digits (A, D)
4 digits (A,C/D)
5. PARAMETERS
1
*1
2
3
4
5
6
7
8
9
10
647