Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual page 183

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

Pr.
Pr.
group
702
C106
706
C130
707
C107
711
C131
712
C132
717
C182
721
C185
724
C108
725
C133
738
C230
739
C231
740
C232
741
C282
742
C285
743
C206
744
C207
745
C208
746
C233
747
G350
753
A650
754
A652
755
A651
756
A653
757
A654
758
A655
759
A600
182
5. PARAMETERS
5.1 Parameter list
Name
Maximum motor frequency 0 to 400 Hz, 9999
Induced voltage constant
(phi f)
Motor inertia (integer)
Motor Ld decay ratio
Motor Lq decay ratio
Starting resistance tuning
compensation
Starting magnetic pole
position detection pulse
width
Motor inertia (exponent)
Motor protection current
level
Second motor induced
voltage constant (phi f)
Second motor Ld decay
ratio
Second motor Lq decay
ratio
Second starting resistance
tuning compensation
Second motor magnetic
pole detection pulse width
Second motor maximum
frequency
Second motor inertia
(integer)
Second motor inertia
(exponent)
Second motor protection
current level
Second motor low-speed
range torque characteristic
selection
Second PID action
selection
Second PID control
automatic switchover
frequency
Second PID action set
point
Second PID proportional
band
Second PID integral time
Second PID differential
time
PID unit selection
Minimum
Setting range
setting
increments
0.01 Hz
0 to 5000 mV (rad/s),
0.1 mV
9999
(rad/s)
10 to 999, 9999
1
0 to 100%, 9999
0.1%
0 to 100%, 9999
0.1%
0 to 200%, 9999
0.1%
0 to 6000 μs,
10000 to 16000 μs,
1μs
9999
0 to 7, 9999
1
100 to 500%, 9999
0.1%
0 to 5000 mV (rad/s),
0.1 mV
9999
(rad/s)
0 to 100%, 9999
0.1%
0 to 100%, 9999
0.1%
0 to 200%, 9999
0.1%
0 to 6000 μs,
10000 to 16000 μs,
1 μs
9999
0 to 400 Hz, 9999
0.01 Hz
10 to 999, 9999
1
0 to 7, 9999
1
100 to 500%, 9999
0.1%
0, 9999
1
0, 10, 11, 20, 21,
50, 51, 60, 61, 70,
71, 80, 81, 90, 91, 100,
101, 1000,
1
1001, 1010, 1011,
2000, 2001, 2010,
2011
0 to 590 Hz, 9999
0.01 Hz
0 to 100%, 9999
0.01%
0.1 to 1000%, 9999
0.1%
0.1 to 3600 s, 9999
0.1 s
0.01 to 10 s, 9999
0.01 s
0 to 43, 9999
1
Initial value
Refer to
Customer
page
setting
FM
CA
9999
519
9999
519
9999
519
9999
519
9999
519
9999
519
9999
519
9999
519
9999
519
9999
519
9999
519
9999
519
9999
519
9999
519
9999
519
9999
519
9999
519
9999
519
9999
227
0
570
9999
570
9999
570
100%
570
1 s
570
9999
570
9999
584