 Selecting the operation mode for power-ON (Pr.340)
• Depending on the Pr.79 and Pr.340 settings, the operation mode at power-ON (reset) changes as described below.
Pr.340
Pr.79
Operation mode at power-ON, at
setting
setting
power restoration, or after a reset
0
(initial
External operation mode
value)
1
PU operation mode
2
External operation mode
0
3, 4
External/PU combined operation mode
(initial value)
6
External operation mode
X12 (MRS) signal ON External operation
mode
7
X12 (MRS) signal OFF External
operation mode
0
NET operation mode
1
PU operation mode
2
NET operation mode
3, 4
External/PU combined operation mode
*1
1, 2
6
NET operation mode
X12 (MRS) signal ON NET operation
mode
7
X12 (MRS) signal OFF External
operation mode
0
NET operation mode
1
PU operation mode
2
NET operation mode
*1
10, 12
3, 4
External/PU combined operation mode
6
NET operation mode
7
External operation mode
*1
Use Pr.340 = "2 or 12" setting to perform communication with the RS-485 terminals. Even if an instantaneous power failure occurs while Pr.57
Restart coasting time ≠ "9999", the inverter continues running at the condition before the instantaneous failure. When Pr.340 = "1 or 10", if a
power failure occurs while the start signal is being input through communication, the start signal is OFF at power restoration.
*2
The operation mode cannot be directly changed between the PU operation mode and Network operation mode.
*3
Switching between the PU and NET operation modes is available with the
Parameters referred to
Pr.57 Restart coasting
timepage
Pr.79 Operation mode
selectionpage 370
597,
page 604
Operation mode switching
Switching among the External, PU, and NET operation modes is
*2
enabled
PU operation mode fixed
Switching among the External, NET operation modes is enabled
Switching to PU operation mode is disabled.
Operation mode switching is disabled
Switching among the External, PU, and NET operation mode is
enabled while running.
Switching among the External, PU, and NET operation modes is
*2
enabled
External operation mode fixed (Forcibly switched to External operation
mode)
Same as Pr.340 = "0" setting
Switching between the PU and NET operation mode is enabled.
Same as Pr.340="0" setting
NET operation mode fixed
Same as Pr.340 = "0" setting
Switching between the PU and NET operation mode is enabled while
*3
running.
Same as Pr.340 = "0" setting
key on the operation panel and the X65 signal.
5.9 (D) Operation command and frequency command
1
2
3
4
5
6
7
*3
8
9
10
379
5. PARAMETERS