8.1
Inverter rating
200 V class
Model FR-A820-[]
SLD
Applicable motor
LD
*1
capacity (kW)
ND (initial setting)
HD
SLD
Rated
LD
capacity
ND (initial setting)
*3
(kVA)
HD
SLD
LD
Rated
current (A)
ND (initial setting)
HD
SLD
Overload
LD
current
ND (initial setting)
*4
rating
HD
*5
Rated voltage
Brake transistor
Maximum brake torque
Regenerative
braking
FR-ABR
(when the option is
used)
Rated input
AC voltage and frequency
Permissible AC voltage fluctuation
Permissible frequency fluctuation
Without DC
reactor
Rated input
*8
current (A)
With DC
reactor
Without DC
reactor
Power supply
capacity
*9
(kVA)
With DC
reactor
Protection rating of structure (IEC 60529)
Cooling system
790
8. SPECIFICATIONS
8.1 Inverter rating
00046 00077 00105 00167 00250 00340 00490 00630 00770 00930 01250 01540 01870 02330 03160 03800 04750
0.4K 0.75K 1.5K 2.2K 3.7K 5.5K 7.5K
0.75
1.5
2.2
3.7
0.75
1.5
2.2
3.7
0.4
0.75
1.5
2.2
*2
0.4
0.75
1.5
0.2
1.8
2.9
4
6.4
1.6
2.7
3.7
5.8
1.1
1.9
3
4.2
0.6
1.1
1.9
3
4.6
7.7
10.5
16.7
4.2
7
9.6
15.2
3
5
8
11
1.5
3
5
8
110% 60 s, 120% 3 s (inverse-time characteristics) at surrounding air temperature of 40°C
120% 60 s, 150% 3 s (inverse-time characteristics) at surrounding air temperature of 50°C
150% 60 s, 200% 3 s (inverse-time characteristics) at surrounding air temperature of 50°C
200% 60 s, 250% 3 s (inverse-time characteristics) at surrounding air temperature of 50°C
Three-phase 200 to 240 V
Built-in
150% torque, 3%
100% torque,
*7
*6
ED
3% ED
150% torque,
100% torque, 10% ED
10% ED
Three-phase 200 to 240 V, 50/60 Hz
170 to 264 V, 50/60 Hz
±5%
SLD
5.3
8.9
13.2
19.7
LD
5
8.3
12.2
18.3
ND
3.9
6.3
10.6
14.1
(initial setting)
HD
2.3
3.9
6.3
10.6
SLD
4.6
7.7
10.5
16.7
LD
4.2
7
9.6
15.2
ND
3
5
8
11
(initial setting)
HD
1.5
3
5
8
SLD
2
3.4
5
7.5
LD
1.9
3.2
4.7
7
ND
1.5
2.4
4
5.4
(initial setting)
HD
0.9
1.5
2.4
4
SLD
1.8
2.9
4
6.4
LD
1.6
2.7
3.7
5.8
ND
1.1
1.9
3
4.2
(initial setting)
HD
0.6
1.1
1.9
3
*10
Enclose type (IP20)
Natural
Forced air
11K
15K 18.5K 22K
5.5
7.5
11
15
18.5
22
5.5
7.5
11
15
18.5
22
3.7
5.5
7.5
11
15
18.5
2.2
3.7
5.5
7.5
11
15
10
13
19
24
29
35
8.8
12
17
22
27
32
6.7
9.1
13
18
23
29
4.2
6.7
9.1
13
18
23
25
34
49
63
77
93
23
31
45
58
70.5
85
17.5
24
33
46
61
76
11
17.5
24
33
46
61
100% torque,
20% torque, continuous
*6
*6
2% ED
100% torque, 6% ED
31.3
45.1
62.8
80.6
96.7
115
28.5
41.6
58.2
74.8
90.9
106
22.6
33.4
44.2
60.9
80
96.3
14.1
22.6
33.4
44.2
60.9
80
25
34
49
63
77
93
23
31
45
58
70.5
85
17.5
24
33
46
61
76
11
17.5
24
33
46
61
12
17
24
31
37
44
11
16
22
29
35
41
8.6
13
17
23
30
37
5.4
8.6
13
17
23
30
10
13
19
24
29
35
8.8
12
17
22
27
32
6.7
9.1
13
18
23
29
4.2
6.7
9.1
13
18
23
30K
37K
45K
55K
90/
30
37
45
55
75
110
30
37
45
55
75
90
22
30
37
45
55
75
18.5
22
30
37
45
55
48
59
71
89
120
145
43
53
65
81
110
132
34
44
55
67
82
110
29
34
44
55
67
82
125
154
187
233
316
380
114
140
170
212
288
346
90
115
145
175
215
288
76
90
115
145
175
215
FR-BU2 (option)
10% torque,
continuous
—
—
—
—
—
151
185
221
269
—
—
139
178
207
255
—
—
113
150
181
216
266
—
96.3
113
150
181
216
—
125
154
187
233
316
380
114
140
170
212
288
346
90
115
145
175
215
288
76
90
115
145
175
215
58
70
84
103
—
—
53
68
79
97
—
—
43
57
69
82
101
—
37
43
57
69
82
—
48
59
71
89
120
145
43
53
65
81
110
132
34
44
55
67
82
110
29
34
44
55
67
82
Open type (IP00)
75K
90K
132
110
90
75
181
165
132
110
475
432
346
288
—
—
—
—
—
475
432
346
288
—
—
—
—
181
165
132
110