 400 V class
Motor model: SF-V5RUH[]K
Applicable inverter model
FR-A840-[]K (ND rating)
Rated output power (kW)
Rated current (A)
Rated torque (N·m)
Maximum torque at 150% 60 s
(N·m)
Rated speed (r/min)
Maximum speed (r/min)
Frame No.
-4
2
Inertia moment J (×10
kg·m
)
*5
Noise
Voltage
Cooling fan
(with
thermal
*3
Input
*7*
protector)
Recommended
8
thermal setting
Surrounding air temperature and
humidity
Structure (Protection rating)
Detector
Equipment
Insulation class
Vibration rank
Approx. mass (kg)
*1
80% output in the high-speed range. (The output is reduced at the speed of 2400 r/min or faster.) Contact us separately for details.
*2
The maximum speed of a 3.7 kW motor or less is 3600 r/min. Consult our sales office for use of these motor.
*3
Power (current) at 50/60 Hz.
*4
Since a brake motor has a window for gap check, the protection rating of both the cooling fan section and brake section of the motor is IP20. The
letter S in IP23S is an additional code indicating that a cooling fan was checked for water protection while it is stationary.
*5
The value shown is applicable to the motor at high carrier frequency (Pr.72 = 6 and Pr.240 = 0).
*6
A separate power supply of 12/24 V is required for the encoder. (When the FR-A8TP is installed on the inverter, the 24 V power supply from the
FR-A8TP is available.)
*7
The cooling fan is equipped with a thermal protector. The cooling fan stops when the coil temperature exceeds the specified value in order to
protect the fan motor. A restrained cooling fan or degraded fan motor insulation could be causes for the rise in coil temperature. The cooling fan
re-starts when the coil temperature drops to normal.
*8
The cooling fan voltage and input values are the basic specifications of the cooling fan alone and free air values. The input value becomes slightly
larger when it is rotated by this motor due to an increased workload, but the cooling fan can be used as it is. When preparing a thermal relay at
the user side, use the recommended thermal setting.
 Motor torque
The torque characteristics of the SF-V5RU series driven by the inverter are shown in graph form as follows.
1
2
3
5
2.2
2.2
3.7
7.5
11
1.5
2.2
3.7
5.5
7.5
4.2
5.8
8.8
14.5
18.5
9.55
14.1
23.6
35.0
47.7
14.3
21.1
35.4
52.4
71.6
90L
100L
112M
132S
132M
67.5
105
175
275
400
75 dB or less
Single-phase 200 V/50 Hz
Single-phase 200 to 230 V/60 Hz
36/55 W
22/28 W
(0.26/0.32 A)
(0.11/0.13 A)
0.36 A
0.18 A
-10 to +40°C (non-freezing), 90% RH or less (non-condensing)
Totally enclosed forced ventilated (Motor: IP44, Cooling fan: IP23S)
Encoder 2048P/R, A phase, B phase, Z phase, +12 V/24 VDC power supply
24
33
41
52
62
7
11
15
18
22
15
18.5
22
30
11
15
18.5
22
27.5
35.5
44
51
70.0
95.5
118
140
105
143
176
211
1500
*2
3000
160M
160L
180M
180M
750
875
1725
1875
Three-phase 380 to 400 V/50 Hz
Three-phase 400 to 460V/60Hz
55/71 W
(0.19/0.19 A)
0.25 A
Encoder, thermal protector, fan
F
V10
99
113
138
160
30
37
45
55
37
45
55
75
*1
*1
*1
55
30
37
45
67
84
99
132
191
235
286
350
287
353
429
525
2400
200L
200L
200L
225S
3250
3625
3625
6850
80 dB or less
85 dB or less
100/156 W
85/130 W
(0.27/0.30 A)
(0.23/0.26 A)
0.39 A
0.34 A
*4
*6
238
255
255
320