Signal
Setting
name
Selection of automatic restart after instantaneous power failure /
flying start
6
CS
Electronic bypass function
7
OH
External thermal relay input
15-speed selection (Combination with multi-speeds of RL, RM, and
8
REX
RH)
9
X9
Third function selection
10
X10
Inverter run enable (FR-HC2/FR-CV/FR-CC2 connection)
FR-HC2/FR-CC2 connection, instantaneous power failure
11
X11
detection
12
X12
PU operation external interlock
13
X13
External DC injection brake operation start
14
X14
PID control valid
15
BRI
Brake opening completion
16
X16
PU/External operation switchover (External operation with X16-ON) Pr.79, Pr.340
Load pattern selection forward/reverse rotation boost (For
17
X17
constant-torque with X17-ON)
18
X18
V/F switchover (V/F control with X18-ON)
19
X19
Load torque high-speed frequency
20
X20
S-pattern acceleration/deceleration C switchover
22
X22
Orientation command (for Vector control compatible options)
23
LX
Pre-excitation/servo ON
Output stop
24
MRS
Electronic bypass function
STP
25
Start self-holding selection
(STOP)
26
MC
Control mode switchover
27
TL
Torque limit selection
28
X28
Start-time tuning start external input
37
X37
Traverse function selection
42
X42
Torque bias selection 1
43
X43
Torque bias selection 2
44
X44
P/PI control switchover (P control with X44-ON)
45
BRI2
Second brake sequence open completion
46
TRG
Trace trigger input
47
TRC
Trace sampling start/end
48
X48
Power failure stop external
50
SQ
Sequence start
51
X51
Fault clear
52
X52
Cumulative pulse monitor clear (for Vector control compatible plug-
in options)
53
X53
Cumulative pulse monitor clear (control terminal option) (for FR-
A8TP)
57
JOGF
JOG forward rotation command
58
JOGR
JOG reverse rotation command
59
CLRN
NET position pulse clear
Forward rotation command (assignable to the STF terminal
60
STF
(Pr.178) only)
Reverse rotation command (assignable to the STR terminal
61
STR
(Pr.179) only)
62
RES
Inverter reset
64
X64
PID forward/reverse action switchover
65
X65
PU/NET operation switchover (PU operation with X65-ON)
66
X66
External/NET operation switchover (NET operation with X66-ON)
Function
*3
*5
Related parameter
Pr.57, Pr.58, Pr.162 to
Pr.165, Pr.299, Pr.611
Pr.57, Pr.58, Pr.135 to
Pr.139, Pr.159
Pr.9
Pr.4 to Pr.6, Pr.24 to Pr.27,
Pr.232 to Pr.239
Pr.110 to Pr.116
Pr.30, Pr.70, Pr.599
Pr.30, Pr.70
Pr.79
Pr.10 to Pr.12
Pr.127 to Pr.134, Pr.575 to
Pr.577
Pr.278 to Pr.285
Pr.14
Pr.80, Pr.81, Pr.800
Pr.270 to Pr.274
Pr.380 to Pr.383
*4*6
Pr.350 to Pr.369
Pr.850
Pr.17
Pr.57, Pr.58, Pr.135 to
Pr.139, Pr.159
Pr.250
Pr.800
Pr.815
Pr.95
Pr.592 to Pr.597
Pr.840 to Pr.845
Pr.840 to Pr.845
Pr.820, Pr.821, Pr.830,
Pr.831
Pr.641 to Pr.648
Pr.1020 to Pr.1047
Pr.1020 to Pr.1047
Pr.261 to Pr.266, Pr.294,
Pr.668
Pr.414
Pr.414
Pr.635
Pr.15, Pr.16
Pr.15, Pr.16
Pr.291, Pr.419 to Pr.430,
Pr.464
Pr.250
Pr.250
Pr.75
Pr.127 to Pr.134
Pr.79, Pr.340
Pr.79, Pr.340
5. PARAMETERS
5.12 (T) Multi-function input terminal parameters
Refer to
page
1
597,
604
532
2
394
391
3
500
689
689
4
370
681
570
5
541
370
674
6
215
549
354
7
554
681
499
8
532
502
9
215
235
527
10
551
255
255
244
541
616
616
610
614
614
306
390
390
305
502
502
320
570
370
370
497

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a820-00167 (2.2k)Fr-a820-00046-gf (0.4k)Fr-a820-00250 (3.7k)Fr-a820-00105-gf (1.5k)Fr-a820-00077 (0.75k)Fr-a820-00250-gf (3.7k) ... Show all

Table of Contents