Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual page 427

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

Monitor item
Fault indication
Set frequency /
motor speed setting
Operation speed
Motor torque
Converter output
*7
voltage
Regenerative brake
*8
duty
Electronic thermal O/
L relay load factor
Output current peak
*7
value
Converter output
*7
voltage peak value
Input power
*9
Output power
Load meter
Motor excitation
*7
current
*11
Position pulse
Cumulative
*3
energization time
*11
Orientation status
Actual operation
*3*4
time
Motor load factor
*7
Cumulative energy
426
5. PARAMETERS
5.11 (M) Item and output signal for monitoring
Pr.52,
communication
Increment
Pr.774 to
and unit
Pr.776,
Pr.992
(hexadecimal)
0/100
*17
*2
H05
0.01 Hz
5
*2
1 (r/min)
H06
6
*2
0.1%
H07
7
*2
0.1 V
H08
8
*2
0.1%
H09
9
*2
0.1%
H0A
10
*6
*2
H0B
0.01/0.1 A
11
*2
0.1 V
H0C
12
0.01/0.1
*2
H0D
13
*6
kW
0.01/0.1
*2
H0E
14
*6
kW
0.1%
17
H11
*6
18
H12
0.01/0.1 A
19
H13
1 h
20
H14
1
22
H16
1 h
23
H17
0.1%
24
H18
0.01/0.1
25
H19
*5*6
kWh
RS-485
MODBUS
RTU real
*1
dedicated
-
time
monitor
monitor
40205
*21
40206
40207
40208
40209
40210
40211
40212
40213
40214
40217
40218
40219
40220
40222
40223
40224
40225
Description
Each of the last 8 faults is displayed individually.
The set frequency is displayed.
The motor speed is displayed (depending on the
settings of Pr.37 and Pr.144). (Refer to
During encoder feedback control operation or
under Vector control, the actual motor speed
according to encoder signals is displayed.
The motor torque is displayed as a percentage
(0% under V/F control), considering the rated
torque as 100%.
The DC bus voltage value is displayed.
Brake duty set in Pr.70 for the regeneration unit
set in Pr.30 is displayed.
The motor thermal cumulative value is displayed,
considering the thermal operation level as 100%.
The peak value of output current, which is
constantly stored, is displayed. (It is reset with
every startup of the inverter.)
The DC bus voltage peak value, which is
constantly stored, is displayed. (It is reset with
every startup of the inverter.)
The power at the inverter input side is displayed.
The power at the inverter output side is displayed.
Torque current is displayed as a percentage,
considering Pr.56 setting value as 100%
(considering the motor rated torque as 100%
under Real sensorless vector control or Vector
control).
The motor excitation current is displayed.
The number of pulses per motor rotation during
orientation control operation or in the position
control mode is displayed. (The output voltage is
displayed when a Vector control option is not
installed.)
The cumulative energization time since the
inverter shipment is displayed.
The number of times an integrated value has
reached the maximum value of 65535 hours can
be checked in Pr.563.
Monitoring is enabled only during orientation
control operation. (The output voltage is displayed
when a Vector control option is not installed.)
(Refer to
page
554.)
The cumulative operation time is displayed.
The number of times an integrated value has
reached the maximum value of 65535 hours can
be checked in Pr.564. Use Pr.171 to reset the
cumulative operation time. (Refer to
The output current value is displayed as a
percentage, considering the inverter rated current
value as 100%.
Readout (%) = present output current value /
inverter rated current value × 100
The cumulative energy based on the monitored
output power is displayed. Use Pr.170 to reset it.
(Refer to
page
432.)
page
422.)
page
433.)