 Copying parameter settings read to the operation panel to the inverter
Operating procedure
1.
Connect the operation panel to the destination inverter.
2.
Selecting the parameter setting mode
Press
to choose the parameter setting mode. (The parameter number read previously appears.)
3.
Selecting the parameter
Turn
to "
"
" appears.
4.
Selecting parameter copy
Turn
to change the set value to "
appears.
5.
Copying to the inverter
Press
to start copying to the inverter. (It takes about 60 seconds to copy all the settings. During copying,
"
● Perform this step while the inverter is stopped. (Parameter settings cannot be copied during operation.)
6.
Ending copying
"
" and "
7.
When parameters are written to the destination inverter, reset the inverter before operation by, for example, turning
the power supply OFF.
NOTE
• "
" appears when a parameter write error occurred. Perform the operation from step 3. again.
• "
" and "
or lower or FR-A840-01800(55K) or lower inverters and the FR-A820-03800(75K) or higher or FR-A840-02160(75K) or higher
inverters. When CP and 0.00 are displayed alternately, set Pr.989 Parameter copy alarm release as shown below (initial
value).
Pr.989 setting
10
100
• After setting Pr.989, perform setting of Pr.9, Pr.30, Pr.51, Pr.56, Pr.57, Pr.61, Pr.70, Pr.72, Pr.80, Pr.82, Pr.90 to Pr.94,
Pr.453, Pr.455, Pr.458 to Pr.462, Pr.557, Pr.859, Pr.860, and Pr.893 again.

5.18.2 Parameter verification

• Whether the parameter settings of inverters are the same or not can be checked.
Operating procedure
1.
Copy the parameter settings of the verification source inverter to the operation panel according to the procedure on
page
708.
2.
Move the operation panel to the inverter to be verified.
3.
Turning ON the power of the inverter
The operation panel is in the monitor mode.
" (Parameter copy), and press
" blinks.)
" are displayed alternately after copying ends.
" are displayed alternately when parameter copy is performed between the FR-A820-03160(55K)
Cancels the alarm of FR-A820-03160(55K) or lower and FR-A840-01800(55K) or lower.
Cancels the alarm of FR-A820-03800(75K) or higher and FR-A840-02160(75K) or higher.
.
", then press
.
Operation
5.18 Copying and verifying parameters on the operation panel
1
2
3
4
5
6
7
8
9
10
709