Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual page 490

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

• Set the bias torque of the terminal 4 input using C38 (Pr.932). (The initial value is the torque for 4 mA.)
• Use C40 (Pr.933) to set the torque to the 20 mA input of the torque command current (4 to 20 mA).
400
150
(-5V)
Bias
(-10V)
C16(Pr.919)
-100%
0
0
0
C17(Pr.919)
-150
∗1
Calibration example of terminal 1
*1
A negative voltage (0 to -10 V (-5 V)) is valid as a torque command. However, when a negative voltage is input as a torque limit value, the torque
limit is regarded as "0".
• There are three methods to adjust the bias/gain torque setting voltage (current).
Adjustment by applying voltage (current) between terminals 1 and 5 (4 and 5) to set the voltage (current) at the bias/gain
page 489
torque.
Adjustment by selecting the voltage (current) at the bias/gain torque without applying voltage (current) between terminals
page 490
1 and 5 (4 and 5).
Adjustment by changing the torque without adjusting the voltage (current).
NOTE
• Always calibrate the input after changing the voltage/current input signal with Pr.73 (Pr.267) and the voltage/current input
selection switch.
 Display unit changing for analog input (Pr.241)
• The analog input display unit (%/V/mA) can be changed for analog input bias/gain calibration.
• Depending on the terminal input specification setting of Pr.73 (Pr.267), the unit of the displayed value of C17 (Pr.919), C19
(Pr.920), C39 (Pr.932), and C41 (Pr.933) changes as shown below:
Analog command (via terminals 1 or
4)
(depending on the setting Pr.73 or
Pr.267)
0 to 5 V input
0 to 10 V input
0 to 20 mA input
 Torque setting voltage (current) bias/gain adjustment method
 Adjustment by applying voltage (current) between terminals 1 and 5 (4 and 5) to set the voltage
(current) at the bias/gain torque
Operating procedure
1.
Turning ON the power of the inverter
The operation panel is in the monitor mode.
2.
Changing the operation mode
Press
to choose the PU operation mode. [PU] indicator turns ON.
3.
Selecting the parameter setting mode
Press
to choose the parameter setting mode. (The parameter number read previously appears.)
Gain
C18(Pr.920)
Initial value
100%
5V
Torque setting signal
10V
C19(Pr.920)
Pr.241 = 0 (initial value)
0 to 100% (0.1%)
0 to 100% (0.1%)
0 to 100% (0.1%)
400
150
Bias
C38
(Pr.932)
0
20
0
4
Torque setting signal
C39(Pr.932)
Calibration example of terminal 4
page 491
0 to 5 V (0.01 V)
0 to 10 V (0.01 V)
0 to 20 mA (0.01 mA)
5.12 (T) Multi-function input terminal parameters
Gain
C40
(Pr.933)
Initial value
100%
20mA
C41(Pr.933)
Pr.241 = 1
489
5. PARAMETERS
1
2
3
4
5
6
7
8
9
10