This is effective in balancing the load when multiple inverters are connected.
Pr.
Name
286
Droop gain
G400
287
Droop filter time constant
G401
288
Droop function activation
G402
selection
994
Droop break point gain
G403
995
Droop break point torque
G404
679
Second droop gain
G420
680
Second droop filter time
G421
constant
681
Second droop function
G422
activation selection
682
Second droop break point
G423
gain
683
Second droop break point
G424
torque
 Droop control
• Droop control is enabled under Advanced magnetic flux vector control, Real sensorless vector control, Vector control, and
PM sensorless vector control.
• In the droop control, the speed command changes depending on the amount of the current for torque.
Set the droop amount at the rated torque in Droop gain as % value of the rated motor frequency (or motor speed when
Pr.288 = "10 or 11").
• The upper limit of the droop compensation frequency is 400 Hz or Pr.1 Maximum frequency, whichever smaller.
Initial value Setting range
0
Normal operation
Droop control enabled.
0%
0.1 to 100%
Set the droop amount at the time of rated torque as % value of
the rated motor frequency.
0.3 s
0 to 1 s
Set the time constant of the filter relative to the torque current.
No droop control during
0
acceleration/deceleration
(with 0 limit)
Continuous droop control
1
during operation
(with 0 limit)
Continuous droop control
2
during operation
(without 0 limit)
No droop control during
10
acceleration/deceleration
(with 0 limit)
0
Continuous droop control
11
during operation
(with 0 limit)
No droop control during
20
acceleration/deceleration
(with 0 limit)
Constant droop control during
21
operation
(with 0 limit)
Constant droop control during
22
operation
(without 0 limit)
Set the droop amount to be changed as % value of the rated
0.1 to 100%
motor frequency.
9999
9999
No function
100%
0.1 to 100%
Set the torque to change the droop amount.
0 to 100%
Refer to Pr.286.
9999
The first droop control setting
9999
is applied.
0 to 1 s
Refer to Pr.287.
9999
The first droop control setting
9999
is applied.
0 to 2, 10, 11,
Refer to Pr.288.
20 to 22
9999
The first droop control setting
9999
is applied.
0.1 to 100%
Refer to Pr.994.
9999
The first droop control setting
9999
is applied.
0.1 to 100%
Refer to Pr.995.
9999
The first droop control setting
9999
is applied.
Description
The Pr.84 setting is the droop
compensation reference.
The motor speed is the droop
compensation reference.
The Pr.1121 setting is the
droop compensation
reference.
Set the second droop control.
The second droop control is
enabled when the RT signal is