Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual page 576

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

• Switch the power voltage/current specifications of terminals 2 and 4 by Pr.73 Analog input selection or Pr.267 Terminal
4 input selection to match the specification of the input device. After changing the Pr.73 or Pr.267 settings, check the
voltage/current input selection switch. Incorrect setting may cause a fault, failure, or malfunction. (Refer to
the setting.)
Pr.128
Pr.609
setting
Pr.610
0
PID invalid
10
Reverse action
11
Invalid
Forward action
20
Reverse action
21
Forward action
40 to 43
Enabled
Dancer control
50
Reverse action
51
Forward action
60
Reverse action
61
Forward action
70
Reverse action
71
Forward action
Invalid
80
Reverse action
81
Forward action
90
Reverse action
91
Forward action
100
Reverse action
101
Forward action
1000
Reverse action
1001
Forward action
1010
Reverse action
1011
Forward action
Reverse action (without
2000
frequency reflected)
Enabled
Forward action (without
2001
frequency reflected)
Reverse action (without
2010
frequency reflected)
Forward action (without
2011
frequency reflected)
*1
When Pr.133 ≠ "9999", the Pr.133 setting is valid.
*2
For the details of CC-Link/CC-Link IE field communication, refer to the Instruction Manual of the option FR-A8NC, FR-A8NCE.
*3
For the details of the PLC function, refer to the FR-A800 PLC Function Programming Manual.
• The set point/deviation input method can also be flexibly selected by Pr.609 PID set point/deviation input selection and
the measured value input method can be selected by Pr.610 PID measured value input selection. Selection by Pr.609
and Pr.610 is valid when Pr.128 = "1000 to 2011".
Pr.609 to Pr.610 settings
1
Terminal 1
2
Terminal 2
3
Terminal 4
4
CC-Link/CC-Link IE Field Network communication
5
PLC function
*4
When the same input method has been selected for the set point and measured value at Pr.609 and Pr.610, set point input is invalid. (Inverter
runs at set point 0%)
PID action
Set point input
Terminal 2 or Pr.133
For details on dancer control, refer to
CC-Link/CC-Link IE Field
Network communication
PLC function
(with frequency applied)
PLC function
(without frequency
*3
applied)
According to Pr.609
According to Pr.609
Input method
*4
*4
*4
Measured value input
*1
Terminal 4
page
590.
CC-Link/CC-Link IE
Field Network
*2
*2
communication
PLC function
(with frequency
*3
*3
applied)
PLC function
(without frequency
*3
applied)
*1
According to Pr.610
*1
According to Pr.610
5.14 (A) Application parameters
1
page 473
for
2
Deviation input
Terminal 1
3
4
CC-Link/CC-Link IE
Field Network
*2
communication
5
PLC function
6
(with frequency
*3
applied)
7
PLC function
(without frequency
*3
applied)
8
9
According to Pr.609
10
According to Pr.609
575
5. PARAMETERS

Hide quick links: