Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual page 522

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

Pr.
Name
453
Second motor capacity 9999
C201
454
Number of second
C202
motor poles
51
Second electronic
C203
thermal O/L relay
456
Rated second motor
C204
voltage
457
Rated second motor
C205
frequency
743
Second motor
C206
maximum frequency
744
Second motor inertia
C207
(integer)
745
Second motor inertia
C208
(exponent)
463
Second motor auto
C210
tuning setting/status
458
Second motor
C220
constant (R1)
Second motor
460
constant (L1) / d-axis
C222
inductance (Ld)
Second motor
461
constant (L2) / q-axis
C223
inductance (Lq)
Second motor torque
860
current/Rated PM
C226
motor current
738
Second motor induced
C230
voltage constant (phi f)
Second motor induced
1413
voltage constant (phi f)
C235
exponent
739
Second motor Ld
C231
decay ratio
740
Second motor Lq
C232
decay ratio
Second starting
741
resistance tuning
C282
compensation
Second motor
742
magnetic pole
C285
detection pulse width
Second motor
746
protection current
C233
level
*1
For the FR-A820-00077(0.75K) or lower and FR-A840-00038(0.75K) or lower, it is set to 85% of the inverter rated current.
*2
For the FR-A820-03160(55K) or lower, and FR-A840-01800(55K) or lower.
Initial
Setting range
value
*2
0.4 to 55 kW
*3
0 to 3600 kW
9999
2, 4, 6, 8, 10, 12
9999
9999
*2
0 to 500 A
9999
*3
0 to 3600 A
9999
200 V/ 400
0 to 1000 V
*4
V
10 to 400 Hz
9999
9999
0 to 400 Hz
9999
9999
9999
10 to 999, 9999
9999
0 to 7, 9999
0, 101
1
0
11
*2*5
0 to 50 Ω, 9999
9999
*3*5
0 to 400 mΩ, 9999
*2*5
0 to 500 mH, 9999
9999
*3*5
0 to 50 mH, 9999
*2*5
0 to 500 mH, 9999
9999
*3*5
0 to 50 mH, 9999
*2*5
0 to 500 A, 9999
9999
*3*5
0 to 3600 A, 9999
0 to 5000 mV (rad/s)
9999
9999
0 to 2
9999
9999
9999
0 to 100%, 9999
9999
0 to 100%, 9999
9999
0 to 200%, 9999
0 to 6000 μs, 10000 to
9999
16000 μs, 9999
100 to 500%
9999
9999
Set the capacity of the second motor.
V/F control
Set the number of poles of the second motor.
V/F control
Set the rated current of the second motor.
The second electronic thermal O/L relay is disabled.
Set the rated voltage (V) of the second motor.
Set the rated frequency (Hz) of the second motor.
The MM-CF constant is used when the IPM motor MM-CF is
selected for the second motor, and the inverter internal data is
used when a PM motor other than MM-CF is selected. Use the
correct setting according to the motor specification.
Set the permissible speed (frequency) of the second motor.
The maximum frequency of an MM-CF motor when MM-CF is
selected.
The Pr.457 setting is used when a motor other than MM-CF is
selected.
Set the motor inertia of the second motor.
9999: The MM-CF inertia is used for the IPM motor MM-CF.
No auto tuning for the second motor.
Offline auto tuning is performed without rotating the motor
(motor other than IPM motor MM-CF).
Offline auto tuning is performed without rotating the motor (for
IPM motor MM-CF).
Tuning data of the second motor
(The value measured by offline auto tuning is automatically
set.)
9999: The MM-CF constant is used when the IPM motor MM-
CF is selected, and the inverter internal data is used when a PM
motor other than MM-CF is selected.
*5
Set this parameter according to the PM motor specifications.
Value calculated based on the tuning data.
Set the exponent n when the induced voltage constant phi f
(Pr.738) is multiplied by 10
No exponent setting
Tuning data of the second motor
(The value measured by offline auto tuning is automatically
set.)
9999: The MM-CF constant is used when the IPM motor MM-
CF is selected, and the inverter internal data is used when a PM
motor other than MM-CF is selected.
Set the maximum current (OCT) level of the second motor.
The MM-CF constant is used when the IPM motor MM-CF is
selected, and 200% when a PM motor other than MM-CF is
selected.
5.13 (C) Motor constant parameters
Description
n
.
5. PARAMETERS
1
2
3
4
5
6
7
8
9
10
521

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a820-00167 (2.2k)Fr-a820-00046-gf (0.4k)Fr-a820-00250 (3.7k)Fr-a820-00105-gf (1.5k)Fr-a820-00077 (0.75k)Fr-a820-00250-gf (3.7k) ... Show all