2.
Connect the fan connectors.
FR-A820-1.5K to 3.7K
FR-A840-2.2K, 3.7K
FR-A820-18.5K, 22K
FR-A840-18.5K, 22K
FR-A820-37K, 45K
FR-A840-37K to 55K
3.
Install the fan cover.
2. Insert hooks
until you hear
1. Insert hooks
a click sound.
into holes.
FR-A820-00105(1.5K) to 00250(3.7K)
FR-A840-00083(2.2K), 00126(3.7K)
NOTE
• Installing the fan in the opposite direction of air flow may shorten the inverter life.
• Ensure that the cables are not caught when the fan is installed.
• Switch OFF the power before starting the fan replacement work. To prevent an electric shock accident, keep the inverter with
its covers on during fans replacement since the inverter circuits are charged with voltage even after power OFF.
Removal (FR-A840-04320(160K) or higher)
1.
Remove the fan cover fixing screws, and remove the fan cover.
2.
Disconnect the fan connector and remove the fan block.
FR-A820-5.5K to 15K
FR-A840-5.5K to 15K
FR-A820-30K
FR-A840-30K
FR-A820-55K or higher
FR-A840-75K or higher
2. Insert hooks
1. Insert hooks
until you
into holes.
hear a click
sound.
FR-A820-00340(5.5K) to 01540(30K)
FR-A840-00170(5.5K) to 00770(30K)
7. PRECAUTIONS FOR MAINTENANCE AND INSPECTION
1. Insert hooks
2. Insert hooks
into holes.
until you
hear a click
sound.
FR-A820-01870(37K) or higher
FR-A840-00930(37K) to 03610(132K)
7.1 Inspection item
1
2
3
4
5
6
7
8
9
10