• The second PID function parameters and signals function in the same way as the following parameters and signals of the
first PID function. Refer to the first PID function when setting the second PID functions.
Classification
127
128
129
130
131
132
133
134
553
Parameter
554
575
576
577
609
610
Classification
X14
Input signal
X64
X72
FUP
FDN
RL
Output signal
PID
SLEEP
Y48
NOTE
• Even if the X14 signal is ON, PID control is stopped and multi-speed or JOG operation is performed when the multi-speed
operation (RH, RM, RL, or REX) signal or JOG signal (JOG operation) is input.
• PID control is invalid under the following settings.
Pr.79 Operation mode selection = "6" (Switchover mode)
• Note that input to the terminal 1 is added to the terminals 2 and 4 inputs. For example when Pr.128 = "20 or 21", the terminal
1 input is considered as a set point and added to the set point of the terminal 2.
• To use terminal 4 and 1 inputs in PID control, set "0" (initial value) to Pr.858 Terminal 4 function assignment and Pr.868
Terminal 1 function assignment. When a value other than "0", PID control is invalid.
• Changing the terminal functions with Pr.178 to Pr.189 and Pr.190 to Pr.196may affect other functions. Set parameters after
confirming the function of each terminal.
• When PID control is selected, the minimum frequency becomes the frequency of Pr.902 and the maximum frequency becomes
the frequency of Pr.903.
(The Pr.1 Maximum frequency and Pr.2 Minimum frequency settings also are valid.)
First PID function parameters
Pr.
Name
PID control automatic switchover
frequency
PID action selection
PID proportional band
PID integral time
PID upper limit
PID lower limit
PID action set point
PID differential time
PID deviation limit
PID signal operation selection
Output interruption detection
time
Output interruption detection
level
Output interruption cancel level
PID set point/deviation input
selection
PID measured value input
selection
First PID function parameters
Signal
Name
PID control valid
PID forward/reverse action
switchover
PID P control switchover
PID upper limit
PID lower limit
PID forward/reverse rotation
output
During PID control activated
PID output interruption
PID deviation limit
Second PID function parameters
Pr.
Second PID control automatic
754
switchover frequency
753
Second PID action selection
756
Second PID proportional band
757
Second PID integral time
1143
Second PID upper limit
1144
Second PID lower limit
755
Second PID action set point
758
Second PID differential time
1145
Second PID deviation limit
1146
Second PID signal operation selection
Second output interruption detection
1147
time
Second output interruption detection
1148
level
1149
Second output interruption cancel level
Second PID set point/deviation input
1140
selection
Second PID measured value input
1141
selection
Second PID function parameters
Signal
X80
Second PID control valid
Second PID forward/reverse action
X79
switchover
X73
Second PID P control switchover
FUP2
Second PID upper limit
FDN2
Second PID lower limit
Second PID forward/reverse rotation
RL2
output
PID2
Second During PID control activated
SLEEP2
During second PID output shutoff
Y205
Second PID deviation limit
5.14 (A) Application parameters
1
Name
2
3
4
5
6
7
Name
8
9
10
583
5. PARAMETERS