Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual page 521

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

Pr.
Name
9
Electronic thermal O/L
C103
relay
83
Rated motor voltage
C104
84
Rated motor frequency 9999
C105
702
Maximum motor
C106
frequency
707
Motor inertia (integer)
C107
724
Motor inertia
C108
(exponent)
96
Auto tuning setting/
C110
status
90
Motor constant (R1)
C120
92
Motor constant (L1)/d-
C122
axis inductance (Ld)
93
Motor constant (L2)/q-
C123
axis inductance (Lq)
859
Torque current/Rated
C126
PM motor current
706
Induced voltage
C130
constant (phi f)
Motor induced voltage
1412
constant (phi f)
C135
exponent
711
Motor Ld decay ratio
C131
712
Motor Lq decay ratio
C132
717
Starting resistance
C182
tuning compensation
Starting magnetic pole
721
position detection
C185
pulse width
725
Motor protection
C133
current level
Lq tuning target
1002
current adjustment
C150
coefficient
450
Second applied motor
C200
520
5. PARAMETERS
5.13 (C) Motor constant parameters
Initial
Setting range
value
Inverter
*2
0 to 500 A
rated
*3
0 to 3600 A
*1
current
200/
0 to 1000 V
*4
400 V
10 to 400 Hz
9999
0 to 400 Hz
9999
9999
9999
10 to 999, 9999
9999
0 to 7, 9999
0, 101
1
0
11
*2*5
0 to 50 Ω, 9999
9999
0 to 400 mΩ, 9999
0 to 500 mH, 9999
9999
*3*5
0 to 50 mH, 9999
0 to 500 mH, 9999
9999
*3*5
0 to 50 mH, 9999
*2*5
0 to 500 A, 9999
9999
*3*5
0 to 3600 A, 9999
0 to 5000 mV (rad/s)
9999
9999
0 to 2
9999
9999
9999
0 to 100%, 9999
9999
0 to 100%, 9999
9999
0 to 200%, 9999
0 to 6000 μs, 10000 to
9999
16000 μs, 9999
100 to 500%
9999
9999
50 to 150%
9999
9999
0, 1, 3 to 6, 13 to 16, 20,
23, 24, 30, 33, 34, 40, 43,
44, 50, 53, 54, 70, 73, 74,
330, 333, 334, 8090,
9999
8093, 8094, 9090, 9093,
9094
9999
Set the rated motor current.
Set the rated motor voltage (V).
Set the rated motor frequency (Hz).
The MM-CF constant is used when the IPM motor MM-CF is
selected, and the inverter internal data is used when a PM
motor other than MM-CF is selected. Use the correct setting
according to the motor specification.
Set the permissible speed (frequency) of the motor.
The MM-CF motor maximum frequency is used when the IPM
motor MM-CF is selected, and Pr.84 setting is used when a PM
motor other than MM-CF is selected.
Set the motor inertia.
9999: The MM-CF inertia is used for the IPM motor MM-CF.
No offline auto tuning
Offline auto tuning is performed without rotating the motor
(motor other than IPM motor MM-CF).
Offline auto tuning is performed without rotating the motor (for
IPM motor MM-CF).
*3*5
Tuning data
*2*5
(The value measured by offline auto tuning is automatically
set.)
9999: The MM-CF constant is used when the IPM motor MM-
*2*5
CF is selected, and the inverter internal data is used when a PM
motor other than MM-CF is selected.
*5
Set this parameter according to the PM motor specifications.
The value calculated from the parameter setting for motor
constant is used.
Set the exponent n when the induced voltage constant phi f
(Pr.706) is multiplied by 10
No exponent setting
Tuning data
(The value measured by offline auto tuning is automatically
set.)
9999: The MM-CF constant is used when the IPM motor MM-
CF is selected, and the inverter internal data is used when a PM
motor other than MM-CF is selected.
Set the maximum current (OCT) level of the motor.
The MM-CF constant is used when the IPM motor MM-CF is
selected, and 200% when a PM motor other than MM-CF is
selected.
Adjust the target current during tuning.
100%
Set this parameter when using the second motor
(the same specifications as Pr.71).
The function is disabled.
Description
n
.