Mitsubishi Electric FR-A820-00046 (0.4K) Instruction Manual page 507

Fr-a800 series
Hide thumbs Also See for FR-A820-00046 (0.4K):
Table of Contents

Advertisement

 Setting the applied motor
• Refer to the following list and set the parameters according to the applied motor.
Pr.71
Pr.450
0
Standard motor (such as SF-JR)
(Pr.71 initial value)
Constant-torque motor (SF-
JRCA, etc.)
1
SF-V5RU (other than the 1500 r/
min series)
Standard motor (such as SF-JR)
2
Adjustable 5 points V/F (refer to
page
Mitsubishi Electric standard motor
20
(SF-JR 4P 1.5kW or lower)
Vector control dedicated motor
30
SF-V5RU (1500 r/min series)
SF-THY
Mitsubishi Electric high-efficiency
40
motor SF-HR
Mitsubishi Electric constant-
50
torque motor SF-HRCA
Mitsubishi Electric high-
70
performance energy-saving motor
SF-PR
*1
IPM motor MM-CF
330
8090
IPM motor (other than MM-CF)
9090
SPM motor
*4
Standard motor (such as SF-JR)
3 (4)
Constant-torque motor (SF-
JRCA, etc.)
*4
13 (14)
SF-V5RU (other than the 1500 r/
min series)
Mitsubishi Electric standard motor
*4
23 (24)
(SF-JR 4P 1.5kW or lower)
Vector control dedicated motor
*4
SF-V5RU (1500 r/min series)
33 (34)
SF-THY
Mitsubishi Electric high-efficiency
*4
43 (44)
motor SF-HR
Mitsubishi Electric constant-
*4
53 (54)
torque motor SF-HRCA
Mitsubishi Electric high-
*4
performance energy-saving motor
73 (74)
SF-PR
*1*4
IPM motor MM-CF
333 (334)
*4
IPM motor (other than MM-CF)
8093 (8094)
*4
SPM motor
9093 (9094)
506
5. PARAMETERS
5.13 (C) Motor constant parameters
Motor
Pr.82 (Pr.455) and Pr.859 (Pr.860)
• 0 to 500 A, 9999 (0.01 A)
• 0 to 3600 A, 9999 (0.1 A)
Pr.90 (Pr.458), Pr.91 (Pr.459)
• 0 to 50 Ω, 9999 (0.001 Ω)
679)
• 0 to 400 mΩ, 9999 (0.01 mΩ)
Pr.92 (Pr.460), Pr.93 (Pr.461) (Induction motor)
• 0 to 6000 mH, 9999 (0.1 mH)
• 0 to 400 mH, 9999 (0.1 mH)
Pr.92 (Pr.460), Pr.93 (Pr.461) (PM motor)
• 0 to 500 mH, 9999 (0.01 mH)
• 0 to 50 mH, 9999 (0.001 mH)
Pr.94 (Pr.462)
• 0 to 100%, 9999 (0.1%)
• 0 to 100%, 9999 (0.01%)
Pr.706 (Pr.738)
• 0 to 5000 mV (rad/s), 9999
Pr.82 (Pr.455), Pr.859 (Pr.860), Pr.90 (Pr.458),
Pr.91 (Pr.459), Pr.92 (Pr.460), Pr.93 (Pr.461),
Pr.94 (Pr.462), Pr.706 (Pr.738)
• Internal data value 0 to 65534, 9999 (1)
The display increment can be changed in Pr.684.
Motor constant value range when performing
offline auto tuning (increment)
*2
*3
*2
*3
*2
*3
*2
*3
*2
*3
(0.1 mV (rad/s))
Electronic thermal O/L relay
function
Constant-
Standard
PM
torque