ABB IRB 7600 Series Product Manual page 100

Hide thumbs Also See for IRB 7600 Series:
Table of Contents

Advertisement

2 Installation and commissioning
2.5.11 Installation of cooling fan for motors (option)
Continued
A
B
C
Installation, separate fan cabling axis 1 or 2
The procedure below details how to install the separate cabling for the cooling fan
of axis 1 or 2.
1
2
3
4
5
6
Continues on next page
100
Cable bracket
Connector R1.SW2/3, connected to the robot base
Connector R3.FAN2, connected to the fan of axis 1 or 2
Action
Move the robot to its calibration position.
DANGER
Turn off all:
electric power supply to the robot
hydraulic pressure supply to the robot
air pressure supply to the robot
Before entering the robot working area.
Remove the rear cover plate from the robot base.
Remove the cable bracket (A)
Fit the plate for customer connections, if not
already fitted, to the connection plate of the robot
base.
Run the cabling up through the base and frame,
beneath the balancing device.
© Copyright 2007 - 2018 ABB. All rights reserved.