ABB IRB 7600 Series Product Manual page 215

Hide thumbs Also See for IRB 7600 Series:
Table of Contents

Advertisement

Cleaning methods
The following table defines what cleaning methods are allowed depending on the
protection type.
Protection
type
Standard
Foundry Plus
i
Cleaning with water and steam
Instructions for rinsing with water
ABB robots with protection types Standard, Foundry Plus, Wash, or Foundry Prime
can be cleaned by rinsing with water (water cleaner).
The following list defines the prerequisites:
I
Instructions for steam or high pressure water cleaning
ABB robots with protection types Foundry Plus, Wash, or Foundry Prime can be
cleaned using a steam cleaner or high pressure water cleaner.
The following list defines the prerequisites:
1
See
Cleaning methods on page 215
2
See
Cleaning methods on page 215
Product manual - IRB 7600
3HAC022033-001 Revision: V
Do not remove any covers or other protective devices before cleaning the
robot.
Cleaning method
Vacuum
Wipe with cloth
cleaner
Yes
Yes. With light
cleaning deter-
gent.
Yes
Yes. With light
cleaning deter-
gent or spirit.
Perform according to section
Maximum water pressure at the nozzle: 700 kN/m
Fan jet nozzle should be used, min. 45° spread
Minimum distance from nozzle to encapsulation: 0.4 meters
Maximum flow: 20 liters/min
Typical tap water pressure and flow
Maximum water pressure at the nozzle: 2500 kN/m
Fan jet nozzle should be used, min. 45° spread
Minimum distance from nozzle to encapsulation: 0.4 meters
Maximum water temperature: 80° C
for exceptions.
for exceptions.
© Copyright 2007 - 2018 ABB. All rights reserved.
Rinse with water
Yes. It is highly re-
commended that
the water contains
a rust-prevention
solution and that
the manipulator is
dried afterwards.
Yes. It is highly re-
commended that
the water contains
a rust-prevention
solution.
Cleaning with water and steam on page
I
3 Maintenance
3.6.2 Cleaning the IRB 7600
Continued
High pressure water or
steam
No
i
Yes
.
It is highly recommended
that the water and steam
contains rust preventive,
without cleaning deter-
gents.
215.
1
2
I
(7 bar)
2
2
(25 bar)
Continues on next page
215

Advertisement

Table of Contents
loading

Table of Contents