4 Repair
4.6.2 Replacement of motor axis 2
Continued
Removal, motor
The procedure below details how to remove the motor, axis 2.
1
2
3
4
5
6
7
8
Continues on next page
320
Action
If the robot is to be calibrated with refer-
ence calibration:
Find previous reference values for the axis
or create new reference values. These val-
ues are to be used after the repair proced-
ure is completed, for calibration of the ro-
bot.
If no previous reference values exist, and
no new reference values can be created,
then reference calibration is not possible.
If the robot is to be calibrated with fine
calibration:
Remove all external cable packages
(DressPack) and tools from the robot.
Action
Decide which calibration routine to
use, and take actions accordingly
prior to beginning the repair proced-
ure.
Move the robot to a position close
enough to its calibration position, to
allow the lock screw to be inserted
into the hole for lock screw .
DANGER
Turn off all:
electric power supply to the
robot
hydraulic pressure supply to
the robot
air pressure supply to the ro-
bot
Before entering the robot working
area.
Lock the lower arm by inserting the
lock screw into the hole.
Drain the oil from gearbox, axis 2.
Remove the cover on top of the mo-
tor by unscrewing its four attach-
ment screws.
Remove the cable gland cover at the
cable exit by unscrewing its two at-
tachment screws.
Disconnect all connectors beneath
the motor cover.
© Copyright 2007 - 2018 ABB. All rights reserved.
Note
Follow the instructions given in the refer-
ence calibration routine on the FlexPendant
to create reference values.
Creating new values requires possibility to
move the robot.
Read more about reference calibration for
Axis Calibration in
routine on page
409.
Read more about reference calibration for
Pendulum Calibration in Operating manu-
al - Calibration Pendulum.
Note
Shown in the figure
Location of motor on page
Art. no. and dimension is specified in
equipment on page
318.
Detailed in the section
Changing oil, axis-2 gear-
box on page
187.
Shown in the figure
Location of motor on page
Make sure the gasket is not damaged!
Product manual - IRB 7600
3HAC022033-001 Revision: V
Reference calibration
318.
Required
318.