Register (Cc-Link) - Mitsubishi Electric MELFA CR750 Series User Manual

Hide thumbs Also See for MELFA CR750 Series:
Table of Contents

Advertisement

12.2.4. Register (CC-Link)

Caution
This can only be used if the CC-Link option card is mounted
This function can only be used with a CRn-500 series or CRnD-700 series robot controller with the
CC-Link option card mounted. Also, this function can no be used with CRnQ-700 series robot
controllers.
You can check the statuses of registers input to the robot controller from outside equipment and registers
output from the robot controller to outside equipment.
From the project tree, double click the target project [Online] -> [Monitor] -> [Signal Monitor] -> [Register
(CC-Link)].
The left side of the screen displays the status of input registers and the right side displays the status of
output registers.
A continuous range of registers to display can be set freely with [Monitor Settings].
Pseudo-input and forced output of registers are also possible.
12.2.4.1. Monitor setting
A continuous range of registers to display can be set freely.
Set the lead numbers for the input register number and output register numbers to display, set their
respective display ranges on the line, then click the [OK] button.
12-241
Figure 12-29 Registers (CC-Link)
in the robot controller.
12-241

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melfa cr700 seriesMelfa cr500 seriesMelfa rt toolbox2Melfa rt toolbox2 min

Table of Contents