11.7.4. DeviceNet parameter

Set the information of DeviceNet in the robot controller. This function can be used with version 3.00A or later of
this software.
Caution
This function can only be used with CR750-D/CRnD-700 series robot controller. Also, this function
cannot be used with CR750-Q/CRnQ-700 series robot controller. If you use CR750-Q/CRnQ-700 series
robot controller, please set it with the software of the PLC.
Set parameters while connected to the robot controller.
From the project tree, double click the target project [Online] -> [Parameter] -> [Filed network parameter] ->
[DeviceNet].
After you change the parameter value, you can rewrite the parameter in the robot controller by clicking the
[Write] button.
You can reset the error of the DeviceNet interface card by pressing the [Err. Cancel] button. After that the
same error doesn't occur. It is valid while the power supply of the robot controller is ON. When the power
supply is turned OFF, the error comes to occur.
You can reference explanation of displayed parameters by pressing the [Explain] button.
11-208
Figure 11-67 DeviceNet parameter
11-208