r7026
CO: Par_circuit max. deviation currents phase V / Phase V Max i_dev
VECTOR_G (Parallel) Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [A]
Description:
Displays the maximum absolute deviation of the measured current actual values of phase V from the average value
as peak value.
The deviation of the individual currents from the average value is displayed in r7021.
Dependency:
Refer to: r7021, r7025, r7027
r7027
CO: Par_circuit max. deviation currents phase W / Phase W Max i_dev
VECTOR_G (Parallel) Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [A]
Description:
Displays the maximum absolute deviation of the measured current actual values of phase W from the average value
as peak value.
The deviation of the individual currents from the average value is displayed in r7022.
Dependency:
Refer to: r7022, r7025, r7026
r7030[0...n]
CO: Par_circuit DC link voltage deviation / Vdc deviation
B_INF (Parallel),
Can be changed: -
VECTOR_G (Parallel)
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [V]
Description:
Displays the deviation of the measured DC link voltage from the average value.
The maximum deviation from the average value is displayed in r7031.
Dependency:
Refer to: r7031
r7031
CO: Par_circuit DC link voltage maximum deviation / Vdc deviation max.
B_INF (Parallel),
Can be changed: -
VECTOR_G (Parallel)
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [V]
Description:
Displays the maximum absolute deviation of the measured DC link voltage from the average value.
The deviation of the individual voltages from the average value is displayed in r7030.
Dependency:
Refer to: r7030
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Calculated: -
Dyn. index: -
Units group: 6_5
Scaling: p2002
Max
- [A]
Calculated: -
Dyn. index: -
Units group: 6_5
Scaling: p2002
Max
- [A]
Calculated: -
Dyn. index: PDS, p0120
Units group: -
Scaling: p2001
Max
- [V]
Calculated: -
Dyn. index: -
Units group: -
Scaling: p2001
Max
- [V]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [A]
Access level: 3
Func. diagram: -
Unit selection: p0505
Expert list: 1
Factory setting
- [A]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [V]
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
- [V]
703