p1134[0...n]
Ramp-function generator rounding-off type / RFG round-off type
VECTOR_G
Can be changed: U, T
Data type: Integer16
P-Group: Setpoints
Not for motor type: -
Min
0
Description:
Sets the smoothed response to the OFF1 command or the reduced setpoint for the extended ramp-function
generator.
Value:
0:
1:
Dependency:
No effect up to initial rounding-off time (p1130) > 0 s.
Note:
p1134 = 0 (continuous smoothing)
If the setpoint is reduced while ramping-up, initially a final rounding-off is carried out and then the ramp-up
completed. During the final rounding-off, the output of the ramp-function generator continues to go in the direction of
the previous setpoint (overshoot). After the final rounding-off has been completed, the output goes toward the new
setpoint.
p1134 = 1 (discontinuous smoothing)
If the setpoint is reduced while ramping-up, then the output goes immediately in the direction of the new setpoint. For
the setpoint change there is no rounding-off.
p1135[0...n]
OFF3 ramp-down time / OFF3 t_RD
VECTOR_G
Can be changed: C2(1), U, T
Data type: FloatingPoint32
P-Group: Setpoints
Not for motor type: -
Min
0.000 [s]
Description:
Sets the ramp-down time from the maximum speed down to zero speed for the OFF3 command.
Note:
This time can be exceeded if the DC link voltage reaches its maximum value.
p1136[0...n]
OFF3 initial rounding-off time / RFGOFF3 t_strt_rnd
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Setpoints
Not for motor type: -
Min
0.000 [s]
Description:
Sets the initial rounding-off time for OFF3 for the extended ramp generator.
p1137[0...n]
OFF3 final rounding-off time / RFG OFF3 t_end_del
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Setpoints
Not for motor type: -
Min
0.000 [s]
Description:
Sets the final rounding-off time for OFF3 for the extended ramp generator.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Cont smoothing
Discont smoothing
Calculated: -
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
1
Calculated: -
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
600.000 [s]
Calculated: -
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
30.000 [s]
Calculated: -
Dyn. index: DDS, p0180
Units group: -
Scaling: -
Max
30.000 [s]
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 3070
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 3060, 3070
Unit selection: -
Expert list: 1
Factory setting
3.000 [s]
Access level: 2
Func. diagram: 3070
Unit selection: -
Expert list: 1
Factory setting
0.000 [s]
Access level: 2
Func. diagram: 3070
Unit selection: -
Expert list: 1
Factory setting
0.000 [s]
305