2 Parameters
2.2 List of parameters
Bit field:
Bit
00
01
02
03
08
09
10
11
p2369
BI: Closed-loop cascade control, control word / Csc_ctrl STW
VECTOR_G
Can be changed: U, T
(Tech_ctrl)
Data type: Unsigned32 / Binary
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for the selection of the "Switch-in motor" function.
When the function is selected, monitoring of the switches is de-activated with the "bypass" function. This means that
the power unit can be connected to other motors via an external control without switch monitoring responding.
p2600
EPOS search for reference reference point offset / Ref_pt offset
B_INF
Can be changed: U, T
Data type: Integer32
P-Group: Basic positioner
Not for motor type: -
Min
-2147482648 [LU]
Description:
Sets the reference point offset for search for reference.
r2700
CO: Reference frequency / f_ref
B_INF
Can be changed: -
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
-
Description:
Display and connector output of the actual reference quantity for the frequency (p2000).
All frequencies specified as relative value are referred to this reference quantity. The reference quantity corresponds
to 100% or 4000 hex (word) or 4000 0000 hex (double word).
This parameter has the unit Hz.
Dependency:
Refer to: p2000
Note:
This BICO parameter provides the numerical value of the reference quantity p2000 as a connector output for
interconnection with Drive Control Chart (DCC). The numerical value can be adopted unchanged from this connector
output in DCC. This BICO parameter is not suitable for interconnecting for cyclic communication.
544
Signal name
Technology controller de-activated
Technology controller limited
Technology controller motorized
potentiometer limited max
Technology controller motorized
potentiometer limited min
Technology controller actual value at the
minimum
Technology controller actual value at the
maximum
Technology controller output at the
minimum
Technology controller output at the
maximum
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
2147482647 [LU]
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
List Manual (LH2), 04/2014, A5E03263479A
0 signal
No
No
No
No
No
No
No
No
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 1
Func. diagram: 3612
Unit selection: -
Expert list: 1
Factory setting
0 [LU]
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
SINAMICS G130/G150
FP
-
-
-
-
-
-
-
-