Rated Motor Torque / Mot M_Rated; Actual Motor-Torque Constant / Mot Kt Act; Motor Cooling Type / Mot Cool Type - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

For IEC motors, the following applies (p0100 = 0):
For p0308 = 0, the internally-calculated power factor is displayed.
For p0308 > 0, this value is displayed.
For NEMA motors, the following applies (p0100 = 1, 2):
For p0309 = 0, the internally-calculated power factor is displayed.
For p0309 > 0, this value is converted into the power factor and displayed.
Dependency:
If p0308 is not entered, the parameter is calculated from the rating plate parameters.
Note:
The parameter is not used for synchronous motors (p0300 = 2xx).
r0333[0...n]

Rated motor torque / Mot M_rated

VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Motor
Not for motor type: -
Min
- [Nm]
Description:
Displays the rated motor torque.
Dependency:
IEC drives (p0100 = 0): unit Nm
NEMA drives (p0100 = 1): unit lbf ft
Note:
For induction and reluctance motors, r0333 is calculated from p0307 and p0311.
For synchronous motors, r0333 is calculated from p0305, p0316, p0327 and p0328. The result can deviate from the
input in p0312. If p0316 = 0, then r0333 = p0312 is displayed.
In the case of multi-motor operation r0333 is increased by the factor p0306 compared to the rated torque of an
individual motor.
r0334[0...n]

Actual motor-torque constant / Mot kT act

VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Motor
Not for motor type: ASM, REL, FEM
Min
- [Nm/A]
Description:
Displays the torque constant of the synchronous motor used.
Dependency:
IEC drives (p0100 = 0): unit Nm / A
NEMA drives (p0100 = 1): unit lbf ft / A
Refer to: p0316
Note:
This parameter is not used for induction motors (p0300 = 1xx).
For synchronous motors, parameter r0334 = p0316 is displayed. For p0316 = 0, r0334 is calculated from p0305 and
p0312 or p0305, p0307, and p0311.
p0335[0...n]

Motor cooling type / Mot cool type

VECTOR_G
Can be changed: C2(1, 3), T
Data type: Integer16
P-Group: Motor
Not for motor type: PEM, REL, FEM
Min
0
Description:
Sets the motor cooling system used.
Value:
0:
1:
2:
4:
5:
6:
128:
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Non-ventilated
Forced cooling
Liquid cooling
Non-ventilated and internal fan
Forced cooling and internal fan
Liquid cooling and internal fan
No fan
Calculated: -
Dyn. index: MDS, p0130
Units group: 7_4
Scaling: -
Max
- [Nm]
Calculated: -
Dyn. index: MDS, p0130
Units group: 28_1
Scaling: -
Max
- [Nm/A]
Calculated: -
Dyn. index: MDS, p0130
Units group: -
Scaling: -
Max
128
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: p0100
Expert list: 1
Factory setting
- [Nm]
Access level: 3
Func. diagram: -
Unit selection: p0100
Expert list: 1
Factory setting
- [Nm/A]
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
129