2 Parameters
2.2 List of parameters
2) Using p2021
--> Only if an address of 0 or an address that is invalid for the fieldbus selected in p2030 has been set using the
address switch.
--> The address is saved in a non-volatile fashion using the function "copy from RAM to ROM".
--> A change only becomes effective after a POWER ON.
Dependency:
Refer to: p2030
Note:
Changes only become effective after POWER ON.
The parameter is not influenced by setting the factory setting.
The parameter is set to the factory setting when the protocol is reselected.
p2022

Field bus int USS PZD no. / Field bus USS PZD

CU_G130_DP,
Can be changed: T
CU_G150_DP
Data type: Unsigned16
P-Group: Communications
Not for motor type: -
Min
0
Description:
Sets the number of 16-bit words in the PZD part of the USS telegram for the field bus interface.
Dependency:
Refer to: p2030
Note:
The parameter is not influenced by setting the factory setting.
p2023

Field bus int USS PKW no. / Field bus USS PKW

CU_G130_DP,
Can be changed: T
CU_G150_DP
Data type: Integer16
P-Group: Communications
Not for motor type: -
Min
0
Description:
Sets the number of 16-bit words in the PKW part of the USS telegram for the field bus interface.
Value:
0:
3:
4:
127:
Dependency:
Refer to: p2030
Note:
The parameter is not influenced by setting the factory setting.
r2029[0...7]

Field bus int error statistics / Field bus error

CU_G130_DP,
Can be changed: -
CU_G150_DP
Data type: Unsigned32
P-Group: Communications
Not for motor type: -
Min
-
Description:
Displays the receive errors on the field bus interface (USS).
Index:
[0] = Number of error-free telegrams
[1] = Number of rejected telegrams
[2] = Number of framing errors
[3] = Number of overrun errors
[4] = Number of parity errors
[5] = Number of starting character errors
[6] = Number of checksum errors
[7] = Number of length errors
464
PKW 0 words
PKW 3 words
PKW 4 words
PKW variable
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
16
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
127
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
List Manual (LH2), 04/2014, A5E03263479A
Access level: 2
Func. diagram: 9310
Unit selection: -
Expert list: 1
Factory setting
2
Access level: 2
Func. diagram: 9310
Unit selection: -
Expert list: 1
Factory setting
127
Access level: 3
Func. diagram: 9310
Unit selection: -
Expert list: 1
Factory setting
-
SINAMICS G130/G150