Measuring Probe 1 Input Terminal / Meas Probe 1 Inp - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Bit field:
Bit
00
01
02
03
04
05
06
07
13
14
15
Notice:
Information on Gn_STW/Gn_ZSW should be taken from the corresponding product documentation.
Note:
The signal source for the encoder control word is set with p0480.
p0488

Measuring probe 1 input terminal / Meas probe 1 inp

ENC
Can be changed: U, T
Data type: Integer16
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Sets the input terminal to connect probe 1.
Value:
0:
1:
2:
3:
4:
5:
6:
7:
8:
Dependency:
Refer to: p0489, p0728
Notice:
To the terminal designation:
The first designation is valid for CU320, the second for CU310.
To select the values:
For CX32, NX10 and NX15, only DI/DO 8, 9, 10, 11 can be selected as fast inputs (refer to the Equipment Manual).
Note:
DI/DO: Bidirectional Digital Input/Output
The terminal must be set as input (p0728).
Refer to the encoder interface for PROFIdrive.
If parameterization is rejected, check whether the terminal is already being used in p0580, p0680, p2517 or p2518.
p0488[0...2]
Measuring probe 1 input terminal / Meas probe 1 inp
VECTOR_G
Can be changed: U, T
Data type: Integer16
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Sets the input terminal to connect probe 1.
Value:
0:
1:
2:
3:
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Signal name
Request function 1
Request function 2
Request function 3
Request function 4
Request command bit 0
Request command bit 1
Request command bit 2
Flying measurement mode/search for
reference mark
Request absolute value cyclic
Request parking encoder
Request acknowledge encoder fault
No meas probe
DI/DO 9 (X122.10/X121.8)
DI/DO 10 (X122.12/X121.10)
DI/DO 11 (X122.13/X121.11)
DI/DO 13 (X132.10/X131.2)
DI/DO 14 (X132.12/X131.4)
DI/DO 15 (X132.13/X131.5)
DI/DO 8 (X122.9/X121.7)
DI/DO 12 (X132.9/X131.1)
No meas probe
DI/DO 9 (X122.10/X121.8)
DI/DO 10 (X122.12/X121.10)
DI/DO 11 (X122.13/X121.11)
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Flying measurement
Yes
Yes
Yes
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
8
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
8
2 Parameters
2.2 List of parameters
0 signal
No
No
No
No
No
No
No
Reference marks
No
No
No
Access level: 3
Func. diagram: 4740
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 3
Func. diagram: 4740
Unit selection: -
Expert list: 1
Factory setting
0
FP
-
-
-
-
-
-
-
-
-
-
-
195

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130