2 Parameters
2.2 List of parameters
r0499

Encoder diagnostic signal high word / Enc diag high word

ENC
Can be changed: -
Data type: Integer16
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the trace signal for encoder diagnostics (high component).
The signal to be output is selected in p0496.
Dependency:
Refer to: p0496, r0497, r0498
r0499[0...2]

CO: Encoder diagnostic signal high word / Enc diag high word

VECTOR_G
Can be changed: -
Data type: Integer16
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the trace signal for encoder diagnostics (high component).
The signal to be output is selected in p0496.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency:
Refer to: p0496, r0497, r0498
p0500

Technology application / Tec application

VECTOR_G
Can be changed: C2(1, 5), T
Data type: Integer16
P-Group: Applications
Not for motor type: -
Min
0
Description:
Sets the technology application.
The parameter influences the calculation of open-loop and closed-loop control parameters that is e.g. initiated using
p0578.
Value:
0:
1:
2:
4:
Dependency:
Refer to: p2175, p2177
Note:
The calculation of parameters dependent on the technology application can be called up as follows:
- when exiting quick commissioning using p3900 > 0
- when writing p0340 = 1, 3, 5
- when writing p0578 = 1
For p0500 = 0, 5 and when the calculation is initiated, the following parameters are set:
p1574 = 10 V (separately-excited synchronous motor: 20 V)
p1611 = 80% (only p0500 = 5)
p1750.2 = 0
p1802 = 4 (SVM/FLB without overcontrol)
p1803 = 106 %
206
Standard drive (VECTOR)
Pumps and fans
Sensorless closed-loop control down to f = 0 (passive loads)
Dynamic in the field weakening range
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
4
List Manual (LH2), 04/2014, A5E03263479A
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
1