Redundant Coarse Position Value Fine Resolution Bits / Fine Bit; Redundant Coarse Position Value Relevant Bits / Relevant Bits; Non Safety-Relevant Measuring Steps Position Value Pos1 / Nsrpos1 - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

r0471

Redundant coarse position value fine resolution bits / Fine bit

ENC
Can be changed: -
Data type: Integer16
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the number of valid bits for the fine resolution of the redundant coarse position value.
Dependency:
Refer to: p9324, p9524
r0471[0...2]
Redundant coarse position value fine resolution bits / Fine bit
VECTOR_G
Can be changed: -
Data type: Integer16
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the number of valid bits for the fine resolution of the redundant coarse position value.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency:
Refer to: p9324, p9524
r0472

Redundant coarse position value relevant bits / Relevant bits

ENC
Can be changed: -
Data type: Unsigned16
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the number of relevant bits for the redundant coarse position value.
r0472[0...2]
Redundant coarse position value relevant bits / Relevant bits
VECTOR_G
Can be changed: -
Data type: Unsigned16
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the number of relevant bits for the redundant coarse position value.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
r0473

Non safety-relevant measuring steps position value pos1 / nsrPos1

ENC
Can be changed: -
Data type: Unsigned32
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the non safety-relevant measuring steps of POS1.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
185

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents