Note:
A higher set access level also includes the lower one.
Access level 1 (standard):
Parameters for simplest possible operations.
Access level 2 (extended):
Parameters to operate the basic functions of the drive unit.
Access level 3 (experts):
Expert know-how is required for these parameters (e.g. BICO parameterization).
Access level 4 (service):
For these parameters, it is necessary that authorized service personnel enter the appropriate password (p3950).
p0004

BOP display filter / BOP disp_filter

CU_G130_DP,
Can be changed: C2(1), U, T
CU_G130_PN,
Data type: Integer16
CU_G150_DP,
P-Group: -
CU_G150_PN
Not for motor type: -
Min
0
Description:
Sets the display filter for parameters with the Basic Operator Panel (BOP).
Value:
0:
1:
2:
3:
4:
5:
7:
8:
10:
12:
13:
14:
15:
17:
18:
19:
20:
21:
25:
28:
47:
50:
90:
95:
98:
99:
Dependency:
Refer to: p0003
Notice:
The display filter via p0004 provides precise filtering and displays the corresponding parameters only when p0009
and p0010 = 0.
Note:
The set access level via p0003 is also relevant for the display filter via p0004.
Examples (assumption: p0009 = p0010 = 0):
p0003 = 1, p0004 = 3
--> Only the parameters for the motor with access level 1 are displayed.
p0003 = 2, p0004 = 3
--> Only the parameters for the motor with access levels 1 and 2 are displayed.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
All parameters
Displays, signals
Power unit
Motor
Encoder/pos enc
Technology/units
Digital inputs/outputs, commands, sequence control
Analog inputs/outputs
Setpoint channel/ramp-fct generator
Functions
U/f control
Control
Data sets
Basic positioner
Gating unit
Motor identification
Communication
Faults, alarms, monitoring functions
Cl-loop pos ctrl
Free function blocks
Trace and function generator
OA parameters
Topology
Safety Integrated
Command Data Sets (CDS)
Drive Data Sets (DDS)
Calculated: -
Dyn. index: -
Units group: -
Scaling: -
Max
99
2 Parameters
2.2 List of parameters
Access level: 1
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0