Co: Torque Limit Lower Without Offset / M_Max Low W/O Offs; Ci: Torque Limit Upper Scaling / M_Max Upper Scal; Ci: Torque Limit Lower Scaling / M_Max Lower Scal; Power Limit Motoring / P_Max Mot - Siemens SINAMICS G150 Manual

Drive converter chassis
Hide thumbs Also See for SINAMICS G150:
Table of Contents

Advertisement

r1527

CO: Torque limit lower without offset / M_max low w/o offs

VECTOR_G (n/M)
Can be changed: -
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
- [Nm]
Description:
Display and connector output for the lower torque limit of all torque limits without offset.
Dependency:
Refer to: p1520, p1521, p1522, p1523, p1528, p1529
p1528[0...n]

CI: Torque limit upper scaling / M_max upper scal

VECTOR_G (n/M)
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
-
Description:
Sets the signal source for the scaling of the upper torque limit in p1522.
Danger:
For p1400.4 = 0 (torque limiting, upper/lower) the following applies:
Negative values resulting from the signal source and scaling can cause the motor to accelerate in an uncontrolled
manner.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p1529[0...n]

CI: Torque limit lower scaling / M_max lower scal

VECTOR_G (n/M)
Can be changed: T
Data type: Unsigned32 / FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
-
Description:
Sets the signal source for the scaling of the lower torque limit in p1523.
Danger:
For p1400.4 = 0 (torque limiting, upper/lower) the following applies:
Positive values resulting from the signal source and scaling can cause the motor to accelerate in an uncontrolled
manner.
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
p1530[0...n]

Power limit motoring / P_max mot

VECTOR_G (n/M)
Can be changed: U, T
Data type: FloatingPoint32
P-Group: Closed-loop control
Not for motor type: REL
Min
0.00 [kW]
Description:
Sets the power limit when motoring.
Dependency:
Refer to: p0500, p1531
Note:
The power limit is limited to 300% of the rated motor power.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Calculated: -
Dyn. index: -
Units group: 7_1
Scaling: p2003
Max
- [Nm]
Calculated: -
Dyn. index: CDS, p0170
Units group: -
Scaling: PERCENT
Max
-
Calculated: -
Dyn. index: CDS, p0170
Units group: -
Scaling: PERCENT
Max
-
Calculated:
CALC_MOD_LIM_REF
Dyn. index: DDS, p0180
Units group: 14_5
Scaling: -
Max
100000.00 [kW]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 6060, 6630,
6640
Unit selection: p0505
Expert list: 1
Factory setting
- [Nm]
Access level: 3
Func. diagram: 6630
Unit selection: -
Expert list: 1
Factory setting
1524[0]
Access level: 3
Func. diagram: 6630
Unit selection: -
Expert list: 1
Factory setting
1525[0]
Access level: 2
Func. diagram: 6640
Unit selection: p0505
Expert list: 1
Factory setting
0.00 [kW]
383

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g130

Table of Contents