Re bit 12 (equidistant zero mark):
The zero marks occur at regular intervals (e.g. rotary encoder with 1 zero mark per revolution or linear encoder with
constant zero mark distance).
The bit activates monitoring of the zero mark distance (p0424/p0425, linear/rotary) or in the case of the linear
encoder with 1 zero mark and p0424 = 0 zero mark monitoring is activated.
Re bit 13 (irregular zero mark):
The zero marks occur at irregular intervals (e.g. a linear scale with only 1 zero mark in the traversing range). The zero
mark distance is not monitored.
Re bit 14 (distance-coded zero mark):
The distance (clearance) between two or several consecutive zero marks allows the absolute position to be
calculated.
Re bit 15 (commutation with zero mark):
Only applicable for synchronous motors.
The function can be de-selected by priority via p0430.23.
For distance-coded zero marks, the following applies:
The phase sequence of the C/D track (if available) must be the same as the phase sequence of the encoder (A/B
track).
The phase sequence of the Hall signal (if available) must be the same as the phase sequence of the motor. Further,
the position of the Hall sensor must be mechanically adjusted to the motor EMF.
The fine synchronization is only started after two zero marks have been passed.
p0405[0...n]

Square-wave encoder track A/B / Sq-wave enc A/B

ENC, VECTOR_G
Can be changed: C2(4)
Data type: Unsigned32
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Settings for the track A/B in a square-wave encoder.
For square-wave encoders, p0404.3 must also be 1.
Bit field:
Bit
00
01
02
03
04
05
Notice:
This parameter is automatically pre-set for encoders from the encoder list (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
Note:
Re bit 02:
When the function is activated, track monitoring can be de-activated by setting p0437.26.
Re bit 05:
When the function is activated, a frequency setpoint and a direction for traveling can be entered via an encoder
interface.
p0407[0...n]

Linear encoder grid division / Enc grid div

ENC, VECTOR_G
Can be changed: C2(4)
Data type: Unsigned32
P-Group: Encoder
Not for motor type: -
Min
0 [nm]
Description:
Sets the grid division for a linear encoder.
154
Signal name
Signal
Level
Track monitoring
Zero pulse
Switching threshold
Pulse/direction
Calculated: -
Dyn. index: EDS, p0140
Units group: -
Scaling: -
Max
-
1 signal
Bipolar
TTL
A/B <> -A/B
Same as A/B track
High
Active
Calculated: -
Dyn. index: EDS, p0140
Units group: -
Scaling: -
Max
250000000 [nm]
List Manual (LH2), 04/2014, A5E03263479A
Access level: 3
Func. diagram: 4704
Unit selection: -
Expert list: 1
Factory setting
0000 1111 bin
0 signal
Unipolar
HTL
None
24 V unipolar
Low
Inactive
Access level: 3
Func. diagram: 4010, 4704
Unit selection: -
Expert list: 1
Factory setting
16000 [nm]