Dependency:
The following applies: p2182 < p2183 < p2184
Refer to: p2182, p2183, p2189, p2190
Note:
In order that the load monitoring can reliably respond, the speed threshold p2184 should always be set higher than
the maximum motor speed to be monitored.
p2185[0...n]

Load monitoring torque threshold 1 upper / M_thresh 1 upper

VECTOR_G (Ext msg) Can be changed: U, T
Data type: FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
0.00 [Nm]
Description:
Sets the speed/torque / velocity/force envelope curve for the load monitoring.
Dependency:
The following applies: p2185 > p2186
Refer to: p2182, p2186
Note:
The upper envelope curve is defined by p2185, p2187 and p2189.
p2186[0...n]
Load monitoring torque threshold 1 lower / M_thresh 1 lower
VECTOR_G (Ext msg) Can be changed: U, T
Data type: FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
0.00 [Nm]
Description:
Sets the speed/torque / velocity/force envelope curve for the load monitoring.
Dependency:
The following applies: p2186 < p2185
Refer to: p2182, p2185
Note:
The lower envelope curve is defined by p2186, p2188 and p2190.
p2187[0...n]

Load monitoring torque threshold 2 upper / M_thresh 2 upper

VECTOR_G (Ext msg) Can be changed: U, T
Data type: FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
0.00 [Nm]
Description:
Sets the speed/torque / velocity/force envelope curve for the load monitoring.
Dependency:
The following applies: p2187 > p2188
Refer to: p2183, p2188
Note:
The upper envelope curve is defined by p2185, p2187 and p2189.
p2188[0...n]
Load monitoring torque threshold 2 lower / M_thresh 2 lower
VECTOR_G (Ext msg) Can be changed: U, T
Data type: FloatingPoint32
P-Group: Messages
Not for motor type: -
Min
0.00 [Nm]
Description:
Sets the speed/torque / velocity/force envelope curve for the load monitoring.
Dependency:
The following applies: p2188 < p2187
Refer to: p2183, p2187
Note:
The lower envelope curve is defined by p2186, p2188 and p2190.
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A
Calculated: -
Dyn. index: DDS, p0180
Units group: 7_1
Scaling: -
Max
20000000.00 [Nm]
Calculated: -
Dyn. index: DDS, p0180
Units group: 7_1
Scaling: -
Max
20000000.00 [Nm]
Calculated: -
Dyn. index: DDS, p0180
Units group: 7_1
Scaling: -
Max
20000000.00 [Nm]
Calculated: -
Dyn. index: DDS, p0180
Units group: 7_1
Scaling: -
Max
20000000.00 [Nm]
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 8013
Unit selection: p0505
Expert list: 1
Factory setting
10000000.00 [Nm]
Access level: 3
Func. diagram: 8013
Unit selection: p0505
Expert list: 1
Factory setting
0.00 [Nm]
Access level: 3
Func. diagram: 8013
Unit selection: p0505
Expert list: 1
Factory setting
10000000.00 [Nm]
Access level: 3
Func. diagram: 8013
Unit selection: p0505
Expert list: 1
Factory setting
0.00 [Nm]